tech-sheet-8206220
Tech Sheet Do not discard
WARNING
Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE
MICROWAVE ENERGY
a. Do not operate or allow the oven to be operated with d. Any defective or misadjusted components in the the door open. interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, b. Make the following safety checks on all ovens to be replaced, or adjusted by procedures described in serviced before activating the magnetron or other service manual before the oven is released to the microwave source, and make repairs as necessary: owner.
1. Interlock Operation e. A microwave leakage check to verify compliance with the CSA should be performed on each oven prior to 2. Proper Door Closing release to the owner.
3. Seal and Sealing Surfaces (Arcing, Wear & Other f. Do not attempt to operate the oven if the door glass is Damage) broken.
4. Damage to or Loosening of Hinges & Latches 5. Evidence of Dropping or Abuse
c. Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity and connections.
8206220 / 4619-651-99051 FOR SERVICE TECHNICIAN’S USE ONLY
AC120V/125V 60Hz Monitor Primary Interlock 2 Switch Fuse Interlock
33BK 20 Amp Switch 4OR
1BK 2BK 6BK 7BR
Cavity 5W Thermostat 2 Electronic Control MW-Relay
AC Line Filter CL L.V. 4903 Relay Transformer 4901 2 1
L 1 3 HF Triac HL Relay HL Relay Red Tube 7104 4911 4912 Black Tube BK L 33K
Pri. 33KSec. WIRING DIAGRAMS 68K 3BR 1 Schematic Diagram 8BU Cy R 31R(HV)
G R Cx 32 Y/G HF Relay Diode 2 White C GND 4902 6101 TTM GND Tube Relay 4906 H.V.Capacitor
Cy
TTM CL L HF2 Door HF1 HL N1 NFS H.V.Diode 1 P2 L P3 1 P4 30Y/G
N 2 4
W 16GY 25BK 14G
17R 15Y 5P5 20R 21W 4P5 Hood F FA 18 R HL Thermistor Magnetron 9BU (Golden (White 1P5 1P6 Magnetron H.V. Cavity (Golden tab) tab) Thermostat Transformer Thermostat 1 tab) BK 26W CL 10BU W HF BU TTM (White 27Y Y 13BU tab) Motor 11 W 19 W Capacitor 28R R
2P5 22W 5P6
23BU
12W 24BU 29W
Secondary DWG NO. MU-074 (Rev. A) Interlock Condition: Door Open Switch P2/P3/P4/P5/P6: Connectors Symbol Notes BK R: Red W: White BR: Brown
HL Hood (Cooktop) Lamp W HF Hood Exhaust Y: Yellow G: Green BU: Blue CL Cavity Lamp BU Fan Motor TTM Turntable Motor OR: Orange GY: Gray BK: Black
Y 1BK
R Wire Color-Black
Wire No.-1
Parts Layout
(not to scale)
A
W B C D
E
F G H
T I
V P5 3551
J
U SR K T Q P L M
O N
A. Hood exhaust fan motor M. Line fuse (20 amp) B. H.V. capacitor N. Power display PCB C. AC line filter O. Electronic control D. Magnetron P. Touch panel E. Magnetron thermostat—opens at 257ºF (125ºC), closes at 185ºF (85ºC) Q. Secondary interlock switch F. Cavity thermostat 1—opens at 221ºF (105ºC), closes at -31ºF (-35ºC) R. Monitor interlock switch G. Cavity thermostat 2—opens at 221ºF (105ºC), closes at -31ºF (-35ºC) S. Primary interlock switch H. H.V. transformer T. Lamp holders I. H.V. diode U. Hood (cooktop) lamp J. Hood thermistor V. Turntable motor K Motor capacitor W. Cavity lamp L. Fuse holder
Primary, Secondary, and Monitor Interlock Switch Checkout Procedures
Switch Check By Door Open Door Closed
1. Unplug microwave oven or disconnect power. – + 2. Disconnect the wires at the Primary Interlock Switch. Primary 3. Check from the common terminal (black/brown wires) to the Interlock normally open terminal (black/white wires). + – 1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Primary Interlock Switch. 3. Check from the common terminal (black/brown wires) to the
normally closed terminal (orange wire).
Secondary 1. Unplug microwave oven or disconnect power. – + Interlock 2. Disconnect the wires at the Secondary Interlock Switch.
3. Check from the common terminal (blue/white wires) to the normally open terminal (blue wires).
3
Primary, Secondary, and Monitor Interlock Switch Checkout Procedures
Switch Check By Door Open Door Closed
1. Unplug microwave oven or disconnect power.
Monitor 2. Disconnect the wires at the Monitor Interlock Switch. + –
Interlock 3. Check from the common terminal (white wire) to the normally
closed terminal (blue/white wires).
(+) Continuity (-) No Continuity
NOTE: These diagrams are not intended to show a complete circuit; they represent the position of switches during “DOOR OPEN” or “DOOR CLOSED” (continuity checks only).
Door Closed Door Open
L (NC) (NO) (NO) N L (NC) (NO) N (NO) (NO) (NC) (NO) (NC)
Primary Monitor Secondary Primary Monitor Secondary Interlock Interlock Interlock Interlock Interlock Interlock Switch Switch Switch Switch Switch Switch
TROUBLESHOOTING
Do not continue with the diagnostics of appliance if the 3. Disconnect white wire from power transformer and household fuse is blown, a circuit breaker is tripped or if there discharge high-voltage capacitor. is less than 120-volt power supply at the wall outlet. 4. All testing must be done with an ohmmeter having a Complete the following steps before checking microwave sensitivity of 20,000 ohms per volt DC or greater, and oven circuitry: powered by at least a 9-volt battery.
1. Unplug microwave oven or disconnect power. 5. All operational checks using microwave energy must be done with the microwave oven loaded with a minimum of 2. Check for loose wiring or incorrect wiring within 8 oz (250 mL) of water in a microwave safe container. microwave oven.
Microwave Cooking
BR 5P2 Electronic Control 1P3 G 4P5 BU L.V. OR Magnetron 3P2 Transformer Fuse Thermostat Cavity BK 2 MW Relay Thermostat 1 L Filter 20 Amp 4903 H.V. Secondary Interlock BK TTM Relay Transformer BK 4906 1 BR W Switch BK BK W BU CL Relay Cavity Primary 4901 BU Thermostat 2 Interlock Switch Turntable Motor
7P2 R R W BU TT 1P5 2P5 W BU Filter
Cavity N Lamp W 6P2 GY CL
HF Triac 2P2 1P6 7104 BK BK 4P2 HF Relay WW
4902 BU BU HF
YY RR
5P6 Motor Capacitor
4
Hood Exhaust Fan on High Automatically
Cavity Electronic Control Cavity Thermostat 1 L Thermostat 2 L.V. Transformer BK BK BK BK BR 5P2 G 4P5 BU W BU 1P3
Filter Fuse 20 Amp W BU
HF Triac BK 1P6 BK 7104 2P2
HF Relay BU BU HF Filter N 4902 W Y Y
RR
P4 5P6 Motor Capacitor
Hood Thermistor
Hood Exhaust Fan on Low Speed
Cavity Electronic Control Cavity Thermostat 1 L Thermostat 2 L.V. Transformer BK BK BK BK BR 5P2 G 4P5 BU W BU 1P3
Filter Fuse W BU 20 Amp
HF Triac W 2P6 W HF Filter 7104 BU BU N 4P2 W HF Relay Y Y
4902
RR
5P6 Motor Capacitor
Hood Exhaust Fan on High / Medium
Cavity Electronic Control Cavity Thermostat 1 L Thermostat 2 L.V. Transformer BK BK BK BK BR 5P2 G 4P5 BU W BU 1P3 W
Filter Fuse BU 20 Amp HF Triac BK1P6 BK 7104 2P2
HF Relay BU BU HF Filter N 4902 W Y Y
RR
5P6 Motor Capacitor
5
Microwave Oven Plugged In—Time of Day Displayed
L Fuse Electronic Control
Filter 20 Amp L.V. 4P5 BU Filter N Transformer BK BK BK BK BR 5P2 G W BU W 1P3 Cavity Cavity Thermostat 1 Thermostat 2
Door Open—Oven Cavity Light is On
Electronic Control Cavity
L.V. 1P3 G 4P5 BU Thermostat 1 N Transformer BR 5P2 W BU W
Fuse OR Filter 3P2 L Filter 20 Amp CL Relay 4901 BK BK BK BK
Cavity 6P2 GY W BU Thermostat 2 CL Primary Cavity Interlock Lamp Switch
Cooktop Light on High
Electronic Control
L Cavity Cavity
Thermostat 2 L.V. Thermostat 1 N
BK BK BK BK BR 5P2 Transformer G 4P5 BU W BU W 1P3
Filter Fuse Filter 20 Amp
HL Relay W 4911 1P2 Y 5P5 R HL Hood (Cooktop) Lamp
Cooktop Light on Low (Night Light)
Electronic Control
L Cavity Cavity
Thermostat 2 L.V. Thermostat 1 N
BK BK BK BK BR 5P2 Transformer G 4P5 BU W BU W 1P3
Filter Fuse Filter 20 Amp
W
HL Relay Diode 4912 6101 1P2 Y 5P5 R
HL
Hood (Cooktop) Lamp
6
Touch Panel
Touch Panel and Electronic Control Test
The microwave hood combination is provided with a self-diagnostic routine that can be accessed through the touch keypad.
To initiate this routine: 2. Release the OFF/CANCEL button and close the door. All 1. Press and hold the OFF/CANCEL button while opening VFD segments will be lit to indicate the test mode has been entered. the door. While still holding the OFF/CANCEL button, unplug the microwave oven for 2 seconds, then plug it NOTE: If the OFF/CANCEL button is pressed during this back in. diagnostic routine, you will exit the test mode.
Key Tables for Test Mode
Key Name Function Display Buzzer Key Name Function Display Buzzer Start – Key 1 1 beep 0 1 beep Light Hi/Lo/Off – Key 3 1 beep 1 – Key 32 1 beep Hood Exhaust – Key 4 1 beep 1 beep Fan (HF) 2 Cavity Light Key 33 1 beep Hi/Med/Lo/Off – On—Relay Turntable On/Off – 3 4901 1 beep Clock – 1 beep Timer Set/Off – 4 Cooktop Light Key 34 1 beep Add 30 Sec – 5 On (High)— Cook Time – Key 5 1 beep 6 Relay 4911 1 beep Cook Power – Key 6 1 beep 1 beep Warm Hold – Key 7 1 beep 7 Microwave Key 35 1 beep Cook – Key 9 1 beep 8 Oven On for Reheat – Key 10 1 beep 10 Seconds— 1 beep Defrost – Key 11 1 beep 9 Relay 4903 Frozen Entrée – Key 12 1 beep Beverage – Key 13 1 beep Off/Cancel (to – Key 36 Popcorn – Key 14 1 beep lock hold, hold Baked Potato – Key 15 1 beep for 3 seconds) – Key 37 Pizza Key 16 1 beep Key 17 1 beep Cavity Light & Key 38 Key 18 1 beep Turntable On— Key 19 1 beep Relay 4901 & Key 20 1 beep Relay 4906
– Key 39
Cooktop Light Key 40 On (Night)— Relay 4912
HF On (High Key 41 Speed)— Relay 4902 & Triac 7104
Exit Test Mode –
7
Microwave Oven Power Output Test
1. Place 8 oz (250 mL) of lukewarm water in the center of the NOTE: If the water takes longer than 2 minutes to heat, microwave oven. this may indicate either the operating voltage is lower than 110 volts or there is a problem with the microwave 2. Operate on HIGH power level for 2 minutes. Water oven. should be hot.
Failure Codes Indications
NOTE: Many of the problems listed in the chart below may be solved by power cycling: unplug microwave oven or disconnect power. After one minute, plug in microwave oven or reconnect power.
Display Likely Failure Condition Recommended Repair Procedure
Flashing Power failure After a power failure, the colon “:” will be flashing. Press any key to end this colon “:” indication. The colon will then be steady when in standby.
F2 Touch panel failure 1. Unplug microwave oven or disconnect power.
2. Replace touch panel.
3. Replace all parts and panels before operating.
4. Plug in microwave oven or reconnect power.
5. If problem persists, unplug microwave oven or disconnect power.
6. Replace electronic control.
7. Replace all parts and panels before operating.
8. Plug in microwave oven or reconnect power.
F6 MW relay 1. Unplug microwave oven or disconnect power. 2. Check wiring to Relay 4903. 3. Check to see if the relay (4903 on relay control board) contact has
welded closed. 4. Replace all parts and panels before operating. 5. Plug in microwave oven or reconnect power. 6. If problem persists, unplug microwave oven or disconnect power. 7. Replace electronic control. 8. Replace all parts and panels before operating. 9. Plug in microwave oven or reconnect power.
Component Tests
IMPORTANT:
s Unplug microwave oven or disconnect power. s Conduct a microwave energy test after performing any tests or repairs to the microwave oven. s Remove the lead wires from the related component before conducting any of the following tests. s Check that all wire leads are in the correct positions before operating the microwave oven. s Discharge the high-voltage capacitor and remove the lead wires from the primary winding of the high-voltage s Grasp wire connectors when removing the wire leads transformer before conducting any of the following from microwave oven parts. tests. s All testing must be done with an ohmmeter having a s All operational checks using microwave energy must be sensitivity of 20,000 ohms per volt DC or greater, and done with the microwave oven loaded with a minimum powered by at least a 9-volt battery. of 8 oz (250 mL) of water in a microwave safe container.
Components Test/Results H.V. Transformer 1. Unplug microwave oven or disconnect power. Filament 2. Remove wire leads. (orange/red wires) 3. Measure resistance (ohmmeter scale: Rx1):
Primary s Primary winding: Less than 0.5 ohm (approximate) s Secondary winding: 80 ohms (approximate) Secondary (white wire – s Filament winding: 0 ohms ground to transformer case) 4. Measure resistance (ohmmeter scale: Rx1k): s Primary winding to grounding: Normal: Infinite s Filament winding to grounding: Normal: Infinite
8
Components Test/Results Magnetron 1. Unplug microwave oven or disconnect power. H.V. Capacitor 2. Remove wire leads. Check that the seal is in good condition. H.V. Diode 3. Measure resistance (ohmmeter scale: Rx1): Turntable Motor Motor Capacitor s Filament terminal: Normal: Less than 1 ohm Hood Exhaust Fan Motor 4. Measure resistance (ohmmeter scale: Rx1k):
Hood Thermistor s Filament to chassis: Normal: Infinite
1. Unplug microwave oven or disconnect power. 2. Discharge capacitor. 3. Measure resistance (ohmmeter scale: Rx1k):
s Terminal to terminal: Normal: Momentarily indicates several ohms, gradually returns to Infinite
s Terminal to case: Normal: Infinite
NOTE: Some inexpensive meters may indicate infinite resistance in both directions. 1. Unplug microwave oven or disconnect power. 2. Measure resistance (ohmmeter scale: Rx1k):
s Forward: Normal: Continuity; Abnormal: Infinite s Reverse: Normal: Infinite; Abnormal: Continuity
1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance (ohmmeter scale: Rx1k):
s Turntable Motor—Normal: 2.7k-3.8k ohms (approximate); Abnormal: Infinite
1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: (ohmmeter scale: Rx1k):
s Normal: Momentarily 0 ohms, then goes to infinite s Abnormal: Infinite
1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance (ohmmeter scale: Rx1):
s High Speed—Normal: Red (R) and Blue (BU) wires: 100-200 ohms (approximate); Blue (BU) and Black (BK) wires: 40-100 ohms (approximate); Abnormal: Infinite
s Low Speed—Normal: Red (R) and Blue (BU) wires: 100-200 ohms (approximate); Blue (BU) and White (W) wires: 80-150 ohms (approximate); Abnormal: Infinite
1. If “NTC SHORT, CALL FOR SERVICE” or “NTC OPEN, CALL FOR SERVICE” scrolls on display, unplug microwave oven or disconnect power.
2. Replace hood thermistor.
P5 3551
AC Line Filter 1. Unplug microwave oven or disconnect power.
1 2 2. Remove wire leads.
3 1U 2 3. Measure resistance (ohmmeter scale: Rx1): s Normal: 1-3 (coil): Less than 1 ohm; 2-4 (coil): Less than 1 ohm; L N 4 3-4 (resistor): 550k-800k ohms s Abnormal: Infinite 3 4
Thermostats NOTE: Refer to “Parts Layout” for opening and closing temperatures.
Cavity Thermostats 1. Unplug microwave oven or disconnect power. Magnetron Thermostat 2. Remove wire leads. 3. Measure continuity (ohmmeter scale: Rx1):
s Cavity and Magnetron Thermostats—Normal: Continuity; Abnormal: Infinite
9
Fiche technique À conserver
AVERTISSEMENT
Risque de choc électrique
Déconnecter la source de courant électrique avant l’entretien.
Replacer pièces et panneaux avant de faire la remise en marche.
Le non-respect de ces instructions peut causer un décès ou un choc électrique.
PRÉCAUTIONS À OBSERVER LORS DES RÉPARATIONS POUR ÉVITER UNE EXPOSITION EXCESSIVE À L’ÉNERGIE DES MICRO-ONDES
a. Ne pas laisser fonctionner le four lorsque la porte est d. Avant de remettre le four à son propriétaire, toute ouverte. défectuosité ou mauvais ajustement de composant affectant interverrouillage, moniteur, joint de porte et b. Sur chaque four, avant d’alimenter le magnétron ou génération/transmission des micro-ondes, devra être une autre source de micro-ondes, exécuter les éliminé par réparation/remplacement/réglage contrôles de sécurité suivants et effectuer les conformément aux procédures décrites dans ce réparations nécessaires : manuel.
1. Système d’interverrouillage—fonctionnement correct e. Avant de remettre l’appareil à son propriétaire, on doit effectuer un test de mesure du taux de fuite de micro- 2. Porte—fermeture correcte ondes, pour vérifier que l’appareil satisfait aux critères des normes CSA. 3. Joint et surfaces de scellement (formation d’arcs, usure et autres détériorations) f. Ne pas tenter de faire fonctionner le four si la fenêtre de la porte est brisée. 4. Charnières et loquets – détérioration ou mauvais ajustements (desserrage)
5. Indices de détérioration par chute ou emploi abusif
c. Avant de mettre le four à micro-ondes sous tension pour des opérations de test ou inspection dans les compartiments de génération de micro-ondes, contrôler magnétron, guide d’ondes/canal de transmission et cavité—contrôler alignement correct, intégrité, connexions.
8206220 / 4619-651-99051 À L’USAGE DU TECHNICIEN SEULEMENT
10
Contacteur Contacteur
interverrouillage Fusible interverrouillage de contrôle 20 A primaire 4 OR
1N 33N 2N 6 N 7 MAR
Thermostat 2 – 5 BL cavité du four Carte des circuits 33KRelais – de commande Transformateur micro-ondes basse tension AC120V/125V 60Hz Filtre sur ligne CA 4903
11 2 1 Tube rouge Tube noir L 1 3 Relais Triac HF Relais HL Relais HL 7104 4911 4912 N CL SCHÉMAS DE CÂBLAGE L 4901 Pri. Schéma des circuits 3MAR Sec. 8BU 1 31R(HV)
Cy R
VE R Cx 32 JA/VE Relais HF Diode 2 Tube C Terre 4902 6101 blanc Relais 33K Terre TTM 68K 4906 Condensateur Cy haute tension
TTM CL L HF2 Porte HF1 HL N1 NFS 30 JA/VE Diode haute 1 P2 tension L P3 1 P4
N 2 4
BL 16 GRIS 25 N 14VE
17R 15JA 20R HL 21BL 4P5 Thermistance F FA 18 R de la hotte Magnétron 9BU 5P5 1P5 (Terminal 1P6 N (Terminal (Terminal Thermostat 1- doré) 26 BL cavité du four 10BU BL doré) blanc) CL BU HF
TTM (Terminal 27JA JA 13BU
blanc) Moteur Transformateur haute tension 11BL condensateur 28 R R 19 BL 2P5 22 BL 5P6
23 BU Thermostat magnétron
12BL 24BU 29 BL
Contacteur Dessin Nº. MU-074 (Rév. A) interverrouillage
secondaire
Situation : Porte Ouverte P2/P3/ P4/ P5/P6: Connecteurs Symboles Lampe – hotte N R : Rouge BL : Blanc MAR : Marron HL (table de cuisson) CL Lampe – cavité du four BL HF Moteur – JA : Jaune VE : Vert BU : Bleu TTM Moteur plateau rotatif ventilateur hotte OR : Orange GRIS : Gris N : Noir BU JA 1 N Fil noir R Fil Nº 1
Répartition des composants
(Pas à l’échelle)
A
W B C D
E
F G H
T I
V P5 3551
J
U K T SR L Q M P
O N
A. Ensemble moteur—ventilateur—hotte M. Fusible (alimentation) (20 A) B. Condensateur haute tension N. Afficheur alimentation PCB C. Filtre sur ligne CA O. Carte des circuits de commande D. Magnétron P. Panneau de commande tactile E. Thermostat—magnétron—ouvert à 257ºF (125ºC), fermé à 185ºF (85ºC) Q. Contacteur interverrouillage secondaire F. Thermostat 1—cavité du four—ouvert à 221ºF (105ºC), fermé à -31ºF (-35ºC) R. Contacteur interverrouillage de contrôle G. Thermostat 2—cavité du four—ouvert à 221ºF (105ºC), fermé à -31ºF (-35ºC) S. Contacteur interverrouillage primaire H. Transformateur haute tension T. Douilles de lampe I. Diode haute tension U. Lampe de la hotte (table de cuisson) J. Thermistance de la hotte V. Moteur plateau rotatif K Moteur condensateur W. Lampe—cavité du four L. Porte-fusible
Processus de contrôle des contacteurs—primaire, secondaire et contrôle
Contacteur Pour contrôler Porte ouverte Porte fermée – + Interverrouillage 1. Débrancher le four à micro-ondes ou déconnecter la source + – primaire de courant électrique.
2. Déconnecter les fils du contacteur d’interverrouillage primaire.
3. Vérifier l’alimentation du connecteur commun (connecteurs noir/marron) au connecteur normalement ouvert (connecteurs noir/blanc).
1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Déconnecter les fils du contacteur d’interverrouillage primaire.
3. Vérifier l’alimentation du connecteur commun (connecteurs noir/marron) au connecteur normalement fermé (connecteur orange).
12
Processus de contrôle des contacteurs—primaire, secondaire et contrôle
Contacteur Pour contrôler Porte ouverte Porte fermée
1. Débrancher le four à micro-ondes ou déconnecter la source
de courant électrique.
Interverrouillage 2. Déconnecter les fils du contacteur d’interverrouillage secondaire. secondaire – +
3. Vérifier l’alimentation du connecteur commun (connecteurs
bleu/blanc) au connecteur normalement ouvert (connecteurs
bleus).
1. Débrancher le four à micro-ondes ou déconnecter la source
de courant électrique.
Interverrouillage 2. Déconnecter les fils du contacteur d’interverrouillage contrôle. contrôle + –
3. Vérifier l’alimentation du connecteur commun (connecteur
blanc) au connecteur normalement fermé (connecteurs bleu/
blanc).
(+) Continuité (-) Circuit ouvert
REMARQUE : Ces schémas ne présentent pas un circuit complet; ils représentent la position des contacteurs pour PORTE OUVERTE ou PORTE FERMÉE (pour contrôle de continuité seulement).
Porte fermée Porte ouverte
L (NF) (NO) (NF) NEU L NEU (NO) (NO) (NF) (NO) (NO) (NF) (NO)
Contacteur Contacteur Contacteur Contacteur Contacteur Contacteur
interverrouillage interverrouillage interverrouillage interverrouillage interverrouillage interverrouillage
primaire contrôle secondaire primaire contrôle secondaire
DÉPANNAGE
Ne pas poursuivre le diagnostic de l’appareil si le fusible est 3. Déconnecter le fil blanc du transformateur grillé, si un disjoncteur est ouvert, ou si la tension d’alimentation, et décharger le condensateur haute d’alimentation de la prise murale est inférieure à 120 volts. tension.
Exécuter les opérations suivantes avant de contrôler les 4. Exécuter tous les contrôles avec un ohmmètre à circuits du four à micro-ondes : résistance interne de 20 000 ohms par volt CC ou plus, alimenté par une pile d’au moins 9 volts. 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 5. Pour tous les contrôles impliquant la génération de micro-ondes, on doit placer une charge à l’intérieur du 2. Rechercher des fils du four à micro-ondes mal connectés four d’au moins 8 oz (250 mL) d’eau dans un récipient ou déconnectés. compatible avec les micro-ondes.
Cuisson aux micro-ondes
Carte des circuits de commande
Tr a n s fo r m a t e u r
MAR 5P2 basse tension VE 4P5 BU Contacteur interverrouillage 1P3 secondaire
Thermostat magnétron L Fusible OR Relais – Transformeur Thermostat 1 – 3P2 micro-ondes cavité du four 20A haute tension Filtre 4903 N N N N N 2 Relais TTM 1 MAR BL BL BU 4906 Thermostat 2 – Contacteur BU cavité du four interverrouillage Relais CL 4901 Moteur – primaire plateau rotatif
7P2 R R TT BL BU 1P5 2P5 BL BU Filtre Lampe – N cavité BL
du four CL 6P2 GRIS
Triac HF 2P2 N 1P6 N 7104 4P2 Relais HF BL BL
4902 BU BU HF
JA JA
RR
5P6 Moteur condensateur
13
Ventilateur—mise en marche automatique à vitesse élevée
Thermostat 2- Carte de circuits de commande Thermostat 1- cavité du four L cavité du four Transformateur
N N N N MAR 5P2 basse tension VE 4P5 BU BL BU
1P3
Filtre Fusible BU 20 A BL
Triac HF N 1P6 N
7104 2P2
Relais HF BU BU HF Filtre N 4902 BL JA JA
P4 R R
5P6 Moteur condensateur
Thermistance de la hotte
Ventilateur—mise en marche à basse vitesse
Thermostat2 – Carte de circuits de commande Thermostat1 – cavité du four L Filtre cavité du four Transformateur
N N N N MAR basse tension VE 4P5 BU BL BU
5P2 1P3
Fusible BL BU 20A
Triac HF BL 2P6 BL 7104
4P2 BU BU HF Filtre N BL Relais HF JA JA 4902
RR
5P6 Moteur condensateur
Ventilateur—mise en marche à vitesse haute/moyenne
Thermostat 2- Carte de circuits de commande Thermostat 1- cavité du four L cavité du four Transformateur
N N N N MAR 5P2 basse tension 1P3 VE 4P5 BU BL BU
Filtre Fusible BL 20A Triac HF BU
7104 2P2 N 1P6 N
Relais HF BU BU HF Filtre N 4902 BL JA JA RR
5P6 Moteur condensateur
14
Four branché—heure affichée
Carte de circuits de commande
L Filtre Fusible Transformateur Filtre N
20 A basse tension 4P5 BU BU
N N N N MAR 5P2 1P3 VE BL BL
Thermostat 2- Thermostat 1- cavité du four cavité du four
Porte ouverte—lampe cavité du four allumée
Carte de circuits de commande Thermostat 1 –
Transformateur cavité du four N basse tension MAR 5P2 1P3 VE 4P5 BU BL BU BL
Thermostat 2 – Fusible OR Filtre 3P2 L cavité du four 20 A Relais CL 4901 N N N N BU
Contacteur 6P2 GRIS CL BL interverrouillage Filtre Lampe – cavité primaire du four
Lampe table de cuisson—éclairage fort
Carte de circuits de commande
L Thermostat 2- Thermostat 1- cavité du four cavité du four Transformateur N BL N N N N MAR 5P2 basse tension VE 4P5 BU BL BU 1P3
Filtre Fusible Filtre 20 A
Relais HL BL 4911 1P2 JA 5P5 R HL Lampe – hotte
(table de cuisson)
Lampe table de cuisson—éclairage faible (veilleuse)
Carte de circuits de commande
L Thermostat 2- Thermostat 1-
cavité du four Transformateur cavité du four N
N N N N MAR 5P2 basse tension VE 4P5 BU BL BU BL 1P3
Filtre Fusible Filtre 20 A
BL
Relais HL Diode 4912 6101 1P2 JA5P5 R
HL
Lampe – hotte (table de cuisson)
15
Tableau de commande tactile
Test du tableau de commande tactile et de la carte des circuits de commande
L’ensemble four à micro-ondes/hotte comporte un système d’autodiagnostic commandé par l’intermédiaire du clavier tactile.
Pour exécuter le processus : 2. Lâcher la touche OFF/CANCEL et fermer la porte. Tous 1. Appuyer sur la touche OFF/CANCEL (Arrêt/annulation) les segments VFD seront allumés pour indiquer que le mode test est en cours. lorsque la porte est ouverte. Tout en appuyant sur la touche OFF/CANCEL, débrancher l’appareil pendant REMARQUE : Si on appuie sur la touche OFF/CANCEL deux secondes, puis rebrancher l’appareil. pendant ce diagnostic, le mode de test est annulé.
Tableau des touches pour le mode de test
Touche Fonction Affichage Avertisseur Touche Fonction Affichage Avertisseur
Start (mise en marche) – Key 1 1 signal Baked Potato – Key 19 1 signal sonore (pommes de terre au four) sonore
Light Hi/Lo/Off (lampe – Key 3 1 signal haute/basse/arrêt) sonore Pizza – Key 20 1 signal
sonore
Hood Exhaust Fan (HF) – Key 4 1 signal sonore Hi/Med/Lo/Off 0 – Key 32 1 signal
(ventilateur haute/med/ sonore
basse/arrêt)
1 Relais 4901 Key 33 1 signal
Turntable (plateau – Key 5 1 signal lampe cavité sonore rotatif) On/Off sonore allumée
Clock (horloge) – Key 6 1 signal 2 Relais 4911 Key 34 1 signal sonore lampe table sonore
de cuisson
Timer Set/Off – Key 7 1 signal allumée (minuterie réglage/ sonore arrêt) (éclairage fort)
3 Relais 4903 Key 35 1 signal
Add 30 Sec (ajouter – Key 9 1 signal Four à micro- sonore 30 secondes) sonore ondes allumé
Cook Time (temps de – Key 10 1 signal pendant cuisson) sonore 10 sec.
Cook Power – Key 11 1 signal 4 – Key 36 1 signal (puissance de sonore chauffage) sonore
5 – Key 37 1 signal
Warm Hold (maintien Key 12 1 signal sonore au chaud) – sonore 6 Relais 4901 et Key 38 1 signal
Cook (cuisson) – Key 13 1 signal Relais 4906 sonore sonore lampe cavité
et plateau
Reheat (réchauffage) – Key 14 1 signal rotatif allumés sonore 7 – Key 39 1 signal
Defrost (décongélation) – Key 15 1 signal sonore sonore 8 Relais 4912 Key 40 1 signal
Frozen Entrée (plat – Key 16 1 signal lampe table sonore surgelé) sonore de cuisson
allumée
Beverage (boisson) – Key 17 1 signal (veilleuse) sonore 9 Relais 4902 et Key 41 1 signal
Popcorn (maïs éclaté) – Key 18 1 signal Triac 7104 sonore sonore Ventilateur
allumé
(vitesse
élevée)
Off/Cancel (arrêt/ Quitter le – 1 signal sonore annulation) (pour mode de test
verrouiller, appuyer
pendant 3 sec.)
16
Test de la puissance du four à micro-ondes
1. Placer un récipient d’eau tiède (8 oz [250 mL]) au centre REMARQUE : Si plus de 2 minutes sont nécessaires du four. pour chauffer l’eau, il se peut que le voltage soit inférieur à 110 volts ou qu’il y ait un problème avec le four à micro- 2. Faire fonctionner le four au niveau de puissance ondes. maximum (HIGH) pendant 2 minutes. L’eau devrait être chaude.
Identification des codes de défaillance
REMARQUE : De nombreux problèmes reportés dans le tableau ci-dessous peuvent être résolus en arrêtant et relançant l’alimentation électrique : débrancher le four à micro-ondes ou déconnecter la source de courant électrique. Après une minute, brancher le four à micro-ondes ou reconnecter la source de courant électrique.
Affichage Défaillance probable Méthode de réparation recommandée
Clignote- Panne Après une panne d’alimentation, on observe le clignotement du “:”. ment “:” d’électricité Appuyer sur une touche quelconque pour mettre fin au clignotement. L’affichage devient stable (mode d’attente).
F2 Défaillance—tableau de 1. Débrancher le four à micro-ondes ou déconnecter la source de courant
commande tactile électrique.
2. Remplacer le tableau de commande.
3. Replacer pièces et panneaux avant de faire la remise en marche.
4. Brancher le four à micro-ondes ou reconnecter la source de courant
électrique.
5. Si le problème persiste, débrancher le four à micro-ondes ou
déconnecter la source de courant électrique.
6. Remplacer la carte des circuits de commande.
7. Replacer pièces et panneaux avant de faire la remise en marche.
8. Brancher le four à micro-ondes ou reconnecter la source de courant
électrique.
F6 Défaillance—relais micro- 1. Débrancher le four à micro-ondes ou déconnecter la source de courant
ondes électrique.
2. Rechercher les conducteurs du relais 4903.
3. Vérifier si le contacteur du relais (4903 sur la carte des circuits de
commande) a été fermé/bloqué par soudure.
4. Replacer pièces et panneaux avant de faire la remise en marche.
5. Brancher le four à micro-ondes ou reconnecter la source de courant
électrique.
6. Si le problème persiste, débrancher le four à micro-ondes ou
déconnecter la source de courant électrique.
7. Remplacer la carte des circuits de commande.
8. Replacer pièces et panneaux avant de faire la remise en marche.
9. Brancher le four à micro-ondes ou reconnecter la source de courant
électrique.
17
Tests des composants
IMPORTANT :
s Débrancher le four à micro-ondes ou déconnecter la s Après tout test ou réparation du four à micro-ondes, source de courant électrique. exécuter un test de contrôle de l’énergie émise.
s Avant d’exécuter les tests suivants, débrancher les fils s Avant de faire fonctionner le four à micro-ondes, vérifier du composant. que tous les fils du câblage sont à la position correcte.
s Décharger le condensateur haute tension et s Pour débrancher les conducteurs des composants du débrancher les conducteurs du bobinage primaire du four à micro-ondes, saisir chaque connecteur. transformateur haute tension avant d’effectuer l’un des tests suivants. s Exécuter tous les contrôles avec un ohmmètre à résistance interne de 20 000 ohms par volt CC ou plus, s Pour tous les contrôles impliquant la génération de alimenté par une pile d’au moins 9 volts. micro-ondes, on doit placer une charge à l’intérieur du four d’au moins 8 oz (250 mL) d’eau dans un récipient compatible avec les micro-ondes.
Composants Test/Résultats Transformateur haute tension 1. Débrancher le four à micro-ondes ou déconnecter la source de courant Bobinage filament électrique. (fils orange/rouge) Bobinage primaire 2. Débrancher les conducteurs. 3. Mesurer la résistance (échelle Rx1 de l’ohmmètre) : Bobinage secondaire (fil blanc – masse – transformateur) s Bobinage primaire : Moins de 0,5 ohm (environ) Magnétron s Bobinage secondaire : 80 ohms (environ) s Bobinage filament : 0 ohm Condensateur haute tension 4. Mesurer la résistance (échelle Rx1k de l’ohmmètre) : s Bobinage primaire—masse : Normal : résistance infinie Diode haute tension s Bobinage filament—masse : Normal : résistance infinie
1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Débrancher les conducteurs. Vérifier que le joint est en bon état. 3. Mesurer la résistance (échelle Rx1 de l’ohmmètre):
s Bobinage filament : Normal : Moins de 1 ohm 4. Mesurer la résistance (échelle Rx1k de l’ohmmètre) :
s Bobinage filament—châssis : Normal : résistance infinie
1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Décharger le condensateur. 3. Mesurer la résistance (échelle Rx1k de l’ohmmètre) :
s Connecteur—connecteur : Normal : indication momentanée d’une résistance de quelques ohms; retour graduel à résistance infinie
s Connecteur—boîtier : Normal : résistance infinie
REMARQUE : Certains instruments peu coûteux peuvent indiquer une résistance infinie dans les deux directions. 1. Débrancher le four à micro-ondes ou déconnecter la source de courant
électrique. 2. Mesurer la résistance (échelle Rx1k de l’ohmmètre) :
s Sens direct : Normal : continuité; Anormal : résistance infinie s Sens inverse : Normal : résistance infinie; Anormal : continuité
18
Composants Test/Résultats Moteur—Plateau rotatif Moteur condensateur 1. Débrancher le four à micro-ondes ou déconnecter la source de courant Moteur ventilateur—hotte électrique.
Thermistance de la hotte 2. Débrancher les conducteurs. 3. Mesurer la résistance (échelle Rx1k de l’ohmmètre) :
s Moteur—plateau rotatif : Normal : 2,7-3,8k ohms (environ); Anormal : résistance infinie
1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Débrancher les conducteurs. 3. Mesurer la résistance (échelle Rx1k de l’ohmmètre) :
s Normal : Indique momentanément 0 ohm puis revient à résistance infinie.
s Anormal : résistance infinie
1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Débrancher les conducteurs. 3. Mesurer la résistance (échelle Rx1 de l’ohmmètre) :
s Vitesse haute—Normal : Conducteurs rouge (R) et bleu (BU) : 100-200 ohms (environ); Conducteurs bleu (BU) et noir (N) : 40-100 ohms (environ); Anormal : résistance infinie
s Vitesse basse—Normal : Conducteurs rouge (R) et bleu (BU) : 100-200 ohms (environ); Conducteurs bleu (BU) et blanc (BL) : 80-150 ohms (environ); Anormal : résistance infinie
1. Si “NTC SHORT, CALL FOR SERVICE” ou “NTC OPEN, CALL FOR SERVICE” défile sur l’afficheur, débrancher le four à micro-ondes ou déconnecter la source de courant électrique.
2. Remplacer la thermistance de la hotte.
P5 3551
Filtre sur ligne CA 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 1 2 2. Débrancher les conducteurs. 3 1U 2 3. Mesurer la résistance (échelle Rx1 de l’ohmmètre) :
L N 4 s Normal : 1-3 (bobine) : moins de 1 ohm; 2-4 (bobine) : moins de 1 ohm; 3-4 (résistance) : 550k-800k ohms 3 4 s Anormal : résistance infinie Thermostats REMARQUE : Pour les températures d’ouverture et de fermeture, voir le Thermostats – schéma de répartition des composants. cavité du four/ 1. Débrancher le four à micro-ondes ou déconnecter la source de courant magnétron électrique. 2. Débrancher les conducteurs. 3. Mesurer la continuité (échelle Rx1 de l’ohmmètre) :
s Thermostats—cavité et magnétron—Normal : continuité; Anormal : résistance infinie
19
8206220 / 4619-651-99051 3/06 FOR SERVICE TECHNICIAN’S USE ONLY À L’USAGE DU TECHNICIEN SEULEMENT