tech-sheet-8205636
Tech Sheet Do not discard
WIRING DIAGRAMS
Schematic Diagram Parts Layout
GND (not to scale)
N L
AC 120V/60Hz
Single Phase Only A
G
W BK
Fuse 20 Amp
N Coil L W AC Line Cx Filter
R BK
Cy Cy
G
Color Symbol Legend A. AC line filter
Symbol Color
W White
R Red
BK Black
BU Blue
Y Yellow
PK Pink
G Green
BR Brown
TROUBLESHOOTING FOR AC LINE FILTER
NOTE: The following diagram, AC line filter diagram, shows the locations of the AC line filter. The second diagram shows an example of the filter locations on all strip circuit diagrams.
AC Line Filter
(L) AC Line Filter AC Line Filter (N) Unit Plugged In BK W Fuse 20A
8205636 FOR SERVICE TECHNICIAN’S USE ONLY
Example: Unit Plugged In
NOTE: This diagram shows an example of the filter locations on all strip circuit diagrams.
(L) AC Line Filter Low Voltage AC Line Filter (N) BK Transformer W Fuse Unit Plugged In 20A Thermostat
Component Test for AC Line Filter
WARNING
Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
Components Test Results AC Line Filter 1. Unplug microwave oven or disconnect power. Normal: s L(1)-L(2) (coil): Less than 1 ohm 2. Remove wire leads. s N(1)-N(2) (coil): Less than 1 ohm Abnormal: Infinite 3. Measure resistance (ohmmeter scale: Rx1): Normal: s L(1) or L(2)-N(1) or N(2) (resistor):
1.5M ohms
Abnormal: 0 ohms
8205636 3/05 FOR SERVICE TECHNICIAN’S USE ONLY