TECH SHEET – DO NOT DISCARD PAGE 1
WARNING Front view Cooling Fan
Electrical Shock Hazard Terminal Block Disconnect power before servicing. Replace all parts and panels before operating. Broil Element Failure to do so can result in death or (frontal view) electrical shock.
DIAGNOSTIC
Disconnect power and perform the following checks:
A potential cause of a control not functioning is corrosion on connections. Observe connections and check for continuity with an ohmmeter.
All tests/checks should be made with a VOM or DVM having a sensitivity of 20,000 per volt DC or greater.
Check all connections before replacing components, looking for broken or loose wires and failed terminals or wires not pressed into connector far enough.
Resistance checks must be made with power cord unplugged from outlet, and with wiring harness or connectors disconnected.
COMPONENTS Hidden Bake Element Rear view (frontal view)
Thermostat Analog Clock Timer Oven Selector Switch Oven Temperature Control
Oven Shutdown Thermal Fuse No. 1 Overtime Thermo
Switch
Lamp Holder
Convection Fan Broil Element Motor (back view)
Oven Shutdown Thermal Fuse No. 2 Hidden Bake Element (back view)
SOFTWARE COPYRIGHTED. THIS PRODUCT IS COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS: U.S. PATENT NOS.
4,852,544 5,175,413 5,422,460 5,571,434 5,808,278 5,910,265 5,983,888 6,087,944 6,263,782 6,403,929 6,663,009 6,722,356 6,930,287 4,974,804 5,185,047 5,424,512 5,620,623 5,810,576 5,918,589 6,008,478 6,097,000 6,349,717 6,437,294 6,666,676 6,734,403 6,935,330 5,008,516 5,321,229 5,438,180 5,694,916 5,813,320 5,924,857 6,017,211 6,111,231 6,363,971 6,509,551 6,693,262 6,784,404 5,064,998 5,349,162 5,441,036 5,749,388 5,841,112 5,928,543 6,035,848 6,163,017 6,375,150 6,545,251 6,698,417 6,841,761 5,138,137 5,378,874 5,491,314 5,756,970 5,856,654 5,961,311 6,043,461 6,201,222 6,392,204 6,570,136 6,698,923 6,870,138 5,142,125 5,382,552 5,571,433 5,767,488 5,881,710 5,967,634 6,079,756 6,232,584 6,394,081 6,614,006 6,700,101 6,904,969
AND OTHER PATENTS PENDING.
FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
TECH SHEET – DO NOT DISCARD PAGE 2
ELECTRICAL COMPONENTS KEY RESULTS ———- OVEN COMPONENTS FRONT/TOP/REAR CHECK POINTS ———- SERVICEABLE ———- Analogic Timer Top ———- ———- Oven Selector Switch Top ———- ———– Oven Thermostat Switch Top ———- 55 to 64 Oven Temperature Contol Top ———- 61 to 71 Overtime Thermo Switch Rear ———- 34 to 40 Oven sel. switch – 2 (W/Y) ———- Bake Element Rear to Oven therm. switch – 2 (BU) Oven sel. switch – 3 (W/R) 20 Internal Broil Rear to Oven therm. switch – 2 (BU) 26 Oven sel. switch – 4 (R) Closed Circuit Broil Rear to Oven therm. switch – 2 (BU) Closed Circuit Incandescent Light ———- Convection Fan Motor Light Bulb-Front ———– Light Assembly-Rear Oven sel. switch – 6 (W/BK) Rear to Neutral (W)
Cooling Fan Motor Top Oven sel. switch – 7 (GY) to Neutral (W) Oven Shutdown Thermal Cutoff Rear No. 2 Automatic Reset Output side of Double Line Break Relay (BK) to (BK) at terminal block Oven Shutdown Thermal Cutoff Top No. 1 Manual Reset Output side of Double Line Break Relay (BK) to (BK) at terminal block Oven Temperature Probe Front ———–
RELAY LOGIC
MODES OBVACEKONENSTAELCETCSTOR IBNRTOIELRNAL BROIL FUNCTIONS PCLIITLOGHNOEHTV.TRLMFAAOMNSPTAT OFF COOLING FAN LIGHT BAKE CONV. BAKE BROIL CONV. BROIL DEFROST
RELAY LOGIC KEY
OFF ON ON OR OFF
FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
TECH SHEET – DO NOT DISCARD PAGE 3
OVEN SELECTOR SWITCH
R – Analogic Timer P1 1 BU – Oven Thermostat Switch
P2 2 W/Y – Bake
P3 3 W/R – Internal Broil
P4 4 R – Broil
P5 5 W – Pilot Lamp
P6 6 W/BK – Convection Fan 7 BK – Analogic Timer P7 GY – Incand. Lamp + Overtime Thermo Switch
OVEN SHUTDOWN THERMAL CUTOFF No. 1 OVEN SHUTDOWN THERMAL CUTOFF No. 2
This oven thermal cutoff is located at the top of This oven thermal cutoff is located at the back of the oven. It will shut down the oven if the the oven. It will shut down the oven if the temperature at the top of the oven exceeds temperature at the back of the oven exceeds component limits. component limits.
It is a manual reset device. It is an automatic reset device.
Thermal Opening Reclose Thermal Opening Reclose Cutoff Temp. Manually Cutoff Temp. Part No. Part No.
4619 615 14601 194°F ± 41°F 4619 615 10801 266°F ± 41°F 230°F ± 41°F 90°C± 5°C 130°C± 5°C 110°C± 5°C
OVEN TEMPERATURE CONTROL OVERTIME THERMO SWITCH
The temperature sensor of this device is located This oven device is located at the back of the inside the oven cavity. It will shut down the oven oven. It will allow the blower (cooling fan) to heating element if the temperature of the oven continue running after the oven is turned off. This cavity reaches 343°C (649°F). allows the oven to cool.
It is an automatic reset device. It is an automatic reset device.
Oven Temperature Opening Temperature Thermal Opening Reclose Control Temp. Resetting Cutoff Temp. Part No. Part No.
4619 615 15211 608°F ± 48°F 597°F ± 37.5°F 4619 615 13951 140°F ± 37.5°F 122°F ±37.5°F 320°C± 9°C 314°C± 3°C 60°C± 3°C 50°C± 3°C
FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
TECH SHEET – DO NOT DISCARD PAGE 4
COMPONENT KEY NOTES:
THERMAL AC DRIVE MOTOR M Cooling fan may continue running after oven is turned off CUTOFF until oven cools.
HEATING Dots indicate connections. ELEMENT Circuit shown in Standby/Off mode with oven door closed.
GROUND
LIGHT OVEN THERMOSTAT PILOT LAMP
OVEN SCHEMATIC
CHASSIS GND N L2 L1 GROUND GY W R BK BROIL GROUND
TEMPERATURE TEMPERATURE OVEN OVEN SHUTDOWN OVEN SHUTDOWN PROBE PROBE THERMAL CUTOFF THERMAL CUTOFF SELECTOR NO. 1 NO. 2 SWITCH MANUAL RESET AUTOMATIC RESET
BU BU BU 1 P1 R BK
21 21 P2 OVEN TEMPERATURE P3 P4 R CONTROL OVEN THERMOSTAT P5
BU BAKE 1000W SWITCH W/Y 2
BU INTERNAL BROIL 900W W/R 3 BK BK R
0 RELAY P1 P2 CONTACT BU BROIL 1600W R4 W5 OVEN THERMOSTAT 0 P1 P2 BR R BU PILOT LAMP ANALOGIC W TIMER
W CONVECTION FAN W/BK 6 P6 W
M
INCANDESCENT GY 7 P7 BR LIGHT
W
COOLING GY FAN 3
W M W/BU 1
OVERTIME 2 BK
THERMO SWITCH
FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
TECH SHEET – DO NOT DISCARD PAGE 5
OVEN STRIP The following individual circuits are for use in diagnosis. Do not continue with the diagnosis of the CIRCUITS appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than a 240 volt (230 volt LIGHT Canada) power supply at the wall outlet.
BAKE N L2 L1
W R BK
OVEN OVEN SHUTDOWN OVEN SHUTDOWN SELECTOR SWITCH THERMAL CUTOFF THERMAL CUTOFF
INCANDESCENT GY 7 P7 BR NO. 1 NO. 2 LIGHT MANUAL RESET AUTOMATIC RESET W
GY R 3 COOLING 2 BK W FAN W/BU 1
OVERTIME BKRELAY BK R THERMO SWITCH 0 CONTACT P1 P2
0 P1 P2 ANALOGIC W BR R TIMER
W
N L2 L1
OVEN W R BK SELECTOR OVEN SHUTDOWN OVEN SHUTDOWN TEMPERATURE OVEN TEMPPREORBAETURETHEORVMENOSTAT PROBE TEMPERTURE SWITCH THERMAL CUTOFF THERMAL CUTOFF
CONTROL SWITCH NO. 1 NO. 2
BU 1 P1 R MANUAL RESET AUTOMATIC RESET
BU BU 21 21
BAKE 1000W R
BU W/Y 2 P2
BU INTERNAL BROIL 900W W/R 3 P3 BK BK R
0 RELAY P1 P2 CONTACT OVEN THERMOSTAT 0 P1 P2 BU PILOT LAMP W 5 P5 ANALOGIC W BR R
TIMER
W
INCANDESCENT GY 7 P7 BR LIGHT
W
COOLING GY 3 W FAN W/BU 1 2 BK
OVERTIME THERMO SWITCH
CONV. BAKE N L2 L1
W R BK
TEMPERATURE OVEN TEMPERATURE OVEN OVEN OVEN SHUTDOWN OVEN SHUTDOWN SELECTOR PROBE TEMPERTURE PROBE THERMOSTAT SWITCH THERMAL CUTOFF THERMAL CUTOFF
CONTROL SWITCH NO. 1 NO. 2
BU MANUAL RESET AUTOMATIC RESET 21 BU BU 1 P1 R
21
BAKE 1000W R
BU W/Y 2 P2 W/R 3 P3 BU INTERNAL BROIL 900W BK BK R
0 RELAY P1 P2 CONTACT OVEN THERMOSTAT 0 P1 P2 BU PILOT LAMP W 5 P5 ANALOGIC W BR R CONVECTION FAN W/BK 6 P6 TIMER W GY 7 P7 BR W INCANDESCENT LIGHT
W
COOLING GY W FAN W/BU 1 3
2 BK
OVERTIME THERMO SWITCH
FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
TECH SHEET – DO NOT DISCARD PAGE 6
OVEN STRIP The following individual circuits are for use in diagnosis. Do not continue with the diagnosis of the CIRCUITS appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than a 240 volt (230 volt BROIL Canada) power supply at the wall outlet.
CONV. BROIL N L2 L1
DEFROST W R BK
TEMPERATURE OVEN TEMPERATURE OVEN OVEN OVEN SHUTDOWN OVEN SHUTDOWN PROBE TEMPERTURE PROBE THERMOSTAT SELECTOR CONTROL SWITCH THERMAL CUTOFF THERMAL CUTOFF SWITCH NO. 1 NO. 2
MANUAL RESET AUTOMATIC RESET
BU BU BU 1 P1 R
21 21
INTERNAL BROIL 900W R
BU W/R 3 P3
BU BROIL 1600W R 4 P4 BK BK R W 5 P5 OVEN THERMOSTAT 0 RELAY P1 P2 CONTACT BU PILOT LAMP
INCANDESCENT 0 P1 P2 LIGHT BR R ANALOGIC W W GY 7 P7 BR TIMER
W
COOLING GY FAN 3 W W/BU 1 2 BK
OVERTIME THERMO SWITCH
N L2 L1
W R BK
TEMPERATURE OVEN TEMPERATURE OVEN OVEN SHUTDOWN OVEN SHUTDOWN PROBE TEMPERTURE PROBE CONTROL OVEN SELECTOR THERMAL CUTOFF THERMAL CUTOFF THERMOSTAT SWITCH NO. 1 NO. 2
SWITCH MANUAL RESET AUTOMATIC RESET BU BU BU 1 P1 R 21 21
R
BU INTERNAL BROIL 900W W/R 3 P3 BK BK R R 4 P4 BU BROIL 1600W W 5 P5 0 RELAY P1 P2 OVEN THERMOSTAT CONTACT W/BK 6 P6 0 P1 P2 BU PILOT LAMP GY 7 P7 BR ANALOGIC W BR R CONVECTION FAN W TIMER
INCANDESCENT W LIGHT
W
COOLING GY 3 W FAN W/BU 1 2 BK
OVERTIME THERMO SWITCH
N L2 L1
W R BK
OVEN SHUTDOWN OVEN SHUTDOWN
THERMAL CUTOFF THERMAL CUTOFF
NO. 1 NO. 2
MANUAL RESET AUTOMATIC RESET
OVEN R SELECTOR CONVECTION FAN BK BK R W SWITCH W/BK 6 P6 0 RELAY P1 P2 INCANDESCENT CONTACT LIGHT GY 7 P7 BR 0 P1 P2
W
ANALOGIC W BR
TIMER W
COOLING GY 3 W FAN 2 BK W/BU 1
OVERTIME THERMO SWITCH
11/06 FOR SERVICE TECHNICIAN’S USE ONLY PART NO. 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 1
AVERTISSEMENT Vue Avant Ventilateur de refroidissement Risque de choc électrique Bloc de Déconnecter la source de courant électrique connexion avant l’entretien.
Replacer pièces et panneaux avant de faire la remise en marche.
Le non-respect de ces instructions peut causer un décès ou un choc électrique.
DIAGNOSTIC Élément du grill Élément chauffant – (vue avant) cuisson au four (vue avant) Déconnecter la source de courant électrique et exécuter les contrôles suivants :
La corrosion des pièces de connexion est une cause potentielle d’anomalie de fonctionnement des organes de commande. Inspecter les connexions et vérifier la continuité à l’aide d’un ohmmètre.
Exécuter tous les tests ou contrôles à l’aide d’un voltmètre ou multimètre à résistance interne de 20 000 par volt CC ou plus.
Contrôler toutes les connexions avant de remplacer des composants; rechercher conducteurs brisés ou mal branchés, connexions mal réalisées ou fils insuffisamment engagés dans les connecteurs.
Exécuter les mesures de résistance alors que le cordon d’alimentation est débranché de la prise de courant et que les connecteurs des tresses de câblage sont débranchés.
COMPOSANTS
Vue Arrière Thermostat
Commande de la Minuterie/horloge température du four analogique Sélecteur
Coupe-circuit du four thermique N°1
Thermo-commutateur de commande du ventilateur
Por te-lampe
Élément du grill (vue arrière)
Moteur de Coupe-circuit ventilateur convection Élément de cuisson thermique N°2 au four caché (vue arrière)
LOGICIEL PROTÉGÉ PAR LES LOIS SUR LE DROIT D’AUTEUR. CE PRODUIT EST COUVERT PAR L’UN OU PLUSIEURS DES BREVETS SUIVANTS : BREVET AMÉRICAIN N°
4,852,544 5,175,413 5,422,460 5,571,434 5,808,278 5,910,265 5,983,888 6,087,944 6,263,782 6,403,929 6,663,009 6,722,356 6,930,287 4,974,804 5,185,047 5,424,512 5,620,623 5,810,576 5,918,589 6,008,478 6,097,000 6,349,717 6,437,294 6,666,676 6,734,403 6,935,330 5,008,516 5,321,229 5,438,180 5,694,916 5,813,320 5,924,857 6,017,211 6,111,231 6,363,971 6,509,551 6,693,262 6,784,404 5,064,998 5,349,162 5,441,036 5,749,388 5,841,112 5,928,543 6,035,848 6,163,017 6,375,150 6,545,251 6,698,417 6,841,761 5,138,137 5,378,874 5,491,314 5,756,970 5,856,654 5,961,311 6,043,461 6,201,222 6,392,204 6,570,136 6,698,923 6,870,138 5,142,125 5,382,552 5,571,433 5,767,488 5,881,710 5,967,634 6,079,756 6,232,584 6,394,081 6,614,006 6,700,101 6,904,969
ET AUTRES BREVETS EN INSTANCE.
À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 2
COMPOSANTS ÉLECTRIQUES :
COMPOSANTS RÉPARABLE AVANT/ POINTS DE CONTACT RÉSULTATS SUPÉRIEURE/ARRIÈRE ——— ——— ——— Minuterie analogique Supérieure ——— ——— ——— Sélecteur du four Supérieure ——— ——— Contacteur du thermostat du four Supérieure 55 à 64 ——— Commande de la température du four Supérieure 61 à 71 ——— Commutateur du ventilateur Arrière 34 à 40 De commutateur sélection four – Élément cuisson au four Arrière 2 (BL/JA) à commande thermostatique ———
Gril interne Arrière four – 2 (BU) 20
Gril Arrière De commutateur sélection four – 26 Lampe – avant 3 (BL/R) à commande thermostatique four Lampe à incandescence Luminaire – arrière Circuit fermé – 2 (BU) Circuit fermé Moteur de ventilateur convection Arrière De commutateur sélection four – ———- Moteur du ventilateur de Supérieure 4 (R) à commande thermostatique refroidissement Coupe-circuit thermique No 2 Arrière four – 2 (BU) Réarmement automatique Supérieure Coupe-circuit thermique No 1 ———- Réarmement manuel Avant Sonde thermométrique du four De commutateur sélection four – 6 (BL/N) à commande thermostatique
four – Neutre (BL)
De commutateur sélection four – 7 (GRIS) à commande thermostatique four –Neutre (BL)
Côté sortie du relais de disjonction double (N) à (N) sur bloc de connexion.
Côté sortie du relais de disjonction double (N) à (N) sur bloc de connexion.
———-
TABLEAU DE LOGIQUE DES RELAIS – FOURSGGCCÉRRULIIOILLESNICTSNATOTECNETURAERUNUDERFUSOFUDORUUR SYMBOLES DU TABLEAU DE LOGIQUE TVLACLCHEVAAUEIOENMMRSNTPCIPSMVELECOEOTASOCÉNTTTNEMAIATVUOUOIEDRNNFCUDOTIFUUOORUNR MODES ARRÊT
FONCTION ALIMENTÉ ARRÊT LAMPE ALIMENTÉ OU CUISSON AU FOUR NON ALIMENTÉ CUISSON AU FOUR AVEC CONVECTION GRIL GRIL A. VEC CONVECTION DÉCONGÉLATION
À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 3
SÉLECTEUR DU FOUR
R – Minuterie analogique P1 1 BU – Contacteur du N – Minuterie analogique thermostat du four P2 2 P3 3 BL/JA – Cuisson au four P4 4 BL/R – Gril interne P5 5 R – Gril P6 6 BL – Lampe Témoin P7 7 BL/N – Ventilateur convection GRIS- Lampe à incandescence + Ventilateur de refroidissement
COUPE-CIRCUIT THERMIQUE N°1 COUPE-CIRCUIT THERMIQUE N°2
Ce coupe-circuit thermique est situé au sommet Ce coupe-circuit thermique est situé à l’arrière du du four. Il commande l’arrêt de l’alimentation du four. Il commande l’arrêt de l’alimentation du four four si la température à l’arrière du four dépasse si la température à l’arrière du four dépasse la la limite tolérable. limite tolérable.
Il s’agit d’un dispositif à réarmement manuel. Il s’agit d’un dispositif à réarmement automatique.
Coupe-circuit thermique Température Température Coupe-circuit thermique Température Température – produit N° d’ouverture de fermeture produit N° d’ouverture de fermeture
4619 615 14601 194°F ± 41°F Manuel 4619 615 10801 266°F ± 41°F 230°F ± 41°F 90°C± 5°C 130°C± 5°C 110°C± 5°C
COMMANDE DE LA TEMPÉRATURE DU THERMO-COMMUTATEUR DE COMMANDE FOUR DU VENTILATEUR
Le capteur de température de ce dispositif est Ce composant du four est situé à l’arrière du four. situé à l’intérieur de la cavité du four. Il Il permet au ventilateur (ventilateur de commande l’extinction de l’élément de chauffage refroidissement) de continuer de fonctionner du four lorsque la température dans la cavité du après l’arrêt du four. Ceci permet au four de four atteint 343°C (649°F) continuer de refroidir.
Il s’agit d’un dispositif à réarmement Il s’agit d’un dispositif à réarmement automatique. automatique.
Oven Temperature Coupe-circuit thermique Température Température Control de fermeture Part No. Température Température – produit N° d’ouverture d’ouverture de fermeture 122°F ±37,5°F 140°F ± 37,5°F 50°C± 3°C 4619 615 13951 60°C± 3°C
4619 615 15211 608°F ± 48°F 597°F ± 37,5°F 320°C± 9°C 314°C± 3°C
À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 4
SYMBOLE – COMPOSANTS NOTES :
COUPE-CIRCUIT MOTEUR CA M Le ventilateur de refroidissement peut continuer à THERMIQUE fonctionner après l’arrêt du four, jusqu’à ce que le four ait ÉLÉMENT refroidi. MASSE – (CHÂSSIS) CHAUFFANT Les points/cercles identifient les connexions. LAMPE LAMPE TÉMOIN DU THERMOSTAT Circuits représentés au mode attente/arrêt, avec porte du DU FOUR four fermée.
SCHÉMA DES CIRCUITS – FOUR
CHÂSSIS – LIAISON LIAISON NEU L2 L1 À LA TERRE À LA TERRE BL R N GRIL – LIAISON GRIS À LA TERRE
SONDE SONDE COUPE-CIRCUIT COUPE-CIRCUIT THERMOMÉTRIQUE THERMOMÉTRIQUE THERMIQUE THERMIQUE
SÉLECTEUR DU FOUR N° 1 N° 2
RÉARMEMENT RÉARMEMENT
MANUEL AUTOMATIQUE
BU BU BU 1 P1 R N P2 21 21 CONTACTEUR DU THERMOSTAT COMMANDE DE DU FOUR R
LA TEMPÉRATURE DU FOUR BL/JA 2
BU CUISSON AU FOUR 1000W
GRIL INTERNE 900W BL/R 3 P3 N NR BU P1 P2 0 CONTACTEUR DU RELAIS BU GRIL 1600W R4 P4
LAMPE TÉMOIN DU BL 5 P5 0 P1 P2 THERMOSTAT DU FOUR MAR R BU MINUTERIE BL ANALOGIQUE VENTILATEUR
BL CONVECTION BL/N 6 P6 BL M
LAMPE À GRIS 7 P7 MAR INCANDESCENCE
BL
VENTILATEUR GRIS 3 DE REFROIDISSEMENT 2N BL M BL/BU 1
COMMUTATEUR DU VENTILATEUR
À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 5
SCHÉMAS DES Les schémas de circuit suivants sont présentés aux fins des opérations de diagnostic. Ne pas CIRCUITS – FOUR poursuivre le diagnostic de l’appareil si un fusible est grillé, un disjoncteur a sauté ou si la tension LAMPE d’alimentation à la prise murale est inférieure à 240 volts (230 volts Canada).
CUISSON AU FOUR NEU L2 L1
COUPE-CIRCUIT BL RN THERMIQUE COUPE-CIRCUIT LAMPE À SÉLECTEUR DU FOUR N°1 THERMIQUE INCANDESCENCE GRIS 7 P7 MAR RÉARMEMENT N° 2 MANUEL RÉARMEMENT BL AUTOMATIQUE
VENTILATEUR GRIS R 3 DE REFROIDISSEMENT 2N BL BL/BU 1 N NR
COMMUTATEUR DU VENTILATEUR 0 CONTACTEUR P1 P2 DU RELAIS 0 P1 P2 MAR MINUTERIE BL ANALOGIQUE
BL
NEU L2 L1
SONDE COUPE-CIRCUIT COUPE-CIRCUIT BL RN THERMOMÉTRIQUE THERMIQUE THERMIQUE SONDE N°1 N° 2 THERMOMÉTRIQUE SÉLECTEUR DU FOUR RÉARMEMENT RÉARMEMENT MANUEL AUTOMATIQUE
BU BU BU 1 P1 R P2 21 2 1 CONTACTEUR DU
COMMANDE DE LA THERMOSTAT DU FOUR R BL BU TEMPÉRATURE DU FOUR CUISSON AU FOUR 1000W BL/JA 2
BU GRIL INTERNE 900W BL/R 3 P3 N NR
0 CONTACTEUR P1 P2 DU RELAIS LAMPE TÉMOIN DU 0 P1 P2 THERMOSTAT DU FOUR BL 5 P5 MAR R BU MINUTERIE BL ANALOGIQUE
LAMPE À GRIS 7 P7 MAR INCANDESCENCE
BL
VENTILATEUR GRIS 3 DE REFROIDISSEMENT 2N BL BL/BU 1
COMMUTATEUR DU VENTILATEUR
CUISSON AU FOUR AVEC NEU L2 L1 CONVECTION COUPE-CIRCUIT COUPE-CIRCUIT BL RN THERMIQUE THERMIQUE SONDE SONDE N°1 N° 2 THERMOMÉTRIQUE THERMOMÉTRIQUE RÉARMEMENT RÉARMEMENT MANUEL AUTOMATIQUE SÉLECTEUR DU FOUR
BU BU BU 1 P1 R
2 1 COMMANDE DE LA 2 1 CONTACTEUR DU P2 THERMOSTAT P3 TEMPÉRATURE DU FOUR R DU FOUR BU CUISSON AU FOUR 1000W BL/JA 2
BU GRIL INTERNE 900W BL/R 3 N NR
0 CONTACTEUR P1 P2 DU RELAIS LAMPE TÉMOIN DU 0 P1 P2 THERMOSTAT DU FOUR BU BL 5 P5 MINUTERIE BL MAR R BL/N 6 P6 VENTILATEUR CONVECTION ANALOGIQUE BL GRIS 7 P7 MAR BL LAMPE À INCANDESCENCE BL
VENTILATEUR GRIS 3 DE REFROIDISSEMENT 2N BL BL/BU 1
COMMUTATEUR DU VENTILATEUR
À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281
FICHE TECHNIQUE – NE PAS JETER PAGE 6
SCHÉMAS DES Les schémas de circuit suivants sont présentés aux fins des opérations de diagnostic. Ne pas CIRCUITS – FOUR poursuivre le diagnostic de l’appareil si un fusible est grillé, un disjoncteur a sauté ou si la tension d’alimentation à la prise murale est inférieure à 240 volts (230 volts Canada). GRIL NEU L2 L1
SONDE COUPE-CIRCUIT COUPE-CIRCUIT BL R N THERMOMÉTRIQUE SONDE THERMIQUE THERMIQUE THERMOMÉTRIQUE SÉLECTEUR DU FOUR N°1 N° 2
RÉARMEMENT RÉARMEMENT
MANUEL AUTOMATIQUE
BU BU 1 P1 R P3 21 2 1 CONTACTEUR DU THERMOSTAT COMMANDE DE LA TEMPÉRATURE R DU FOUR BL/R 3 BU DU FOUR GRIL INTERNE 900W
BU BU GRIL 1600W R 4 P4 N NR BL 5 P5 LAMPE TÉMOIN DU 0 CONTACTEUR P1 P2 BU THERMOSTAT DU FOUR DU RELAIS
LAMPE À 0 P1 P2 INCANDESCENCE MAR R MINUTERIE BL BL GRIS 7 P7 MAR ANALOGIQUE
BL
VENTILATEUR GRIS DE REFROIDISSEMENT 3
BL BL/BU 1 2N
COMMUTATEUR DU VENTILATEUR
GRIL AVEC CONVECTION NEU L2 L1 DÉCONGÉLATION SONDE COUPE-CIRCUIT COUPE-CIRCUIT BL R N
SONDE THERMIQUE THERMIQUE THERMOMÉTRIQUE THERMOMÉTRIQUE SÉLECTEUR DU FOUR N°1 N° 2
RÉARMEMENT RÉARMEMENT
MANUEL AUTOMATIQUE
BU BU BU 1 P1 R
21 2 1 CONTACTEUR P3 DU THERMOSTAT P4 COMMANDE DE LA DU FOUR P5 R TEMPÉRATURE DU FOUR P6 P7 MAR INTERNAL BROIL 900W N NR
BU BL/R 3 0 CONTACTEUR P1 P2 DU RELAIS BU GRIL INTERNE 1600W R4 0 P1 P2 LAMPE TÉMOIN DU BL 5 MINUTERIE BL MAR R BU THERMOSTAT DU FOUR
VENTILATEUR CONVECTION BL/N 6 ANALOGIQUE BL BL
LAMPE À GRIS 7 INCANDESCENCE
BL
VENTILATEUR GRIS DE REFROIDISSEMENT 3
BL BL/BU 1 2N
COMMUTATEUR
DU VENTILATEUR
NEU L2 L1
BL R N COUPE-CIRCUIT COUPE-CIRCUIT
THERMIQUE THERMIQUE
N°1 N° 2
RÉARMEMENT RÉARMEMENT
MANUEL AUTOMATIQUE
SÉLECTEUR DU FOUR R
VENTILATEUR CONVECTION BL/N 6 P6 N NR BL 0 CONTACTEUR P1 P2 LAMPE À DU RELAIS INCANDESCENCE GRIS 7 P7 MAR 0 P1 P2 BL
MINUTERIE BL MAR
ANALOGIQUE BL
VENTILATEUR GRIS 3 DE REFROIDISSEMENT 1 BL BL/BU 2N
COMMUTATEUR DU VENTILATEUR
11/06 À L’USAGE DU TECHNICIEN SEULEMENT PIÈCE No 461961907281