Model JEC9530AD* JEC9536AD* Power Source @ 120/240/208 V 7.5 kW/5.7 kW 8.8 kW/6.7 kW Electrical rating 31/27 Amp max. 37/32 Amp max. Amperage Frequency 60 Hz 60 Hz Element Wattage @ 240/208 V 6-inch ribbon radiant 1,200 1,200 7-inch ribbon radiant N/A 1,800 8-inch ribbon radiant 2,000 2,000 9/6 inch dual ribbon radiant 3,000/1,400 N/A 12/9 inch dual ribbon radiant N/A Warming Element 120 V 100 100 Cooktop Surface Updraft Cooktop surface Ceran/Eurokera Ceran/Eurokera Product Dimensions in. (cm) Height 3-5/8 (9.2) 3-5/8 (9.2) Width 21-1/2 (54.7) 21-1/2 (54.7) Length 29-15/16 (76.0) 35-5/16 (89.7) Product Cutout Dimensions in. (cm) Width 20-3/8 (51.9) 20-3/8 (51.9) Length 29-1/16 (74.0) 34-9/16 (87.9) Depth (minimum from top of countertop) Weight lbs. (kg) 4-1/4 (10.8) 4-1/4 (10.8) Approximately shipping weight 45 (20.4) 65 (29.4)

June 2003 1 16022397 Rev. 0

Component Testing Procedures

! WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Illustration Component Test Procedure Results 1200 W 6″ Ribbon radiant Remove one wire lead from element Continuity, if not replace. 1800 W 7″ elements and measure resistance of the 6″ 1200W: 44 to 49 Approximately 2000 W 8″ element. 7″ 1800W: 29 to 33 Approximately 3000 W 9/6″ Warming element 8″ 2000W: 26 to 30 Approximately 3000 W 12/9″ Dual element 1400 + 1600 = 3000 W 3000W: 1400 W Inner 53 to 59 Ribbon surface 100 W thermal limiter/hot Dual element 1400 + 1600 = 3000 W 1600 W Outer 38 to 42 light switch 3000W: 1400 W Inner 37 to 42 Remove one wire lead from element and measure resistance of the 1600 W Outer 33 to 37 element. Continuity, if not replace. Turn surface element on and test for 6″ 100W: 35 to 39 Approximately voltage. See wiring diagram and schematic. 240 VAC Therm-O-Disc (TOD)

1a 2a 240 VAC Electrovac 1b 2b 120 VAC 2b 1b Disconnect leads and measure Hot light resistance on the following: 2a circuit

1a 2a room temperature continuity 2b Heater 1a Heater 1b 2b room temperature infinite circuit circuit Hot light circuit 2a 1a 1b

Infinite switch Remove wiring from terminals H1 and Time On Time Off 95% 5 L1 3 Primary Heating Element H2. Connect Volt-ohms meter to LO 5% 50% 4 H2 L2 0% Term. 1 Term. 4 H1 and H2. MED (4-5) 50% H1 H2 Measure the following for voltages at LO, MED, HI: HI 100%

Heater H1 to H2

240 VAC, if not, replace switch.

P Term. 2 Term. 3 P L1 Term. 5 2 L2 1 H1 N L1 L2

Infinite switch Remove wiring from terminals H1 and Time On Time Off 95% Phase H2. Connect Volt-ohms meter to LO 5% 50% 0% 2 (L1) Not Used H1 and H2.

5 (P) MED (4-5) 50%

HI 100%

P Measure the following for voltages at 240 VAC, if not, replace switch. Neutral LO, MED, HI:

H1 to H2

3 (H1) N (L2)

Load

Dual infinite switch Remove wiring from terminals H1 and Time On Time Off 95% EGO TOP H2. Connect Volt-ohms meter to LO 5% 50% 0% P1 (L1, 2) H1 and H2. MED (4-5) 50% EGO (H1, 3) P1 Measure the following for voltages at HI 100% LO, MED, HI: 4 2 4 ELEMENT 240 VAC, if not, replace switch. P2 H1 to H2 4a 4a 2 S2 S1 (H2, 4) S2 P2 (P, 5) (L2)

S1

Indicator light Measure voltage at indicator light. If voltage is present and light does not work replace light. If no voltage is present at indicator light check wiring.

16022397 Rev. 0 2 June 2003

Component Testing Procedures

! WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Illustration Component Test Procedure Results Cooling fan Remove wire leads from terminals and measure resistance of the motor. 667 Ohms, If 0 or infinite ohms, replace motor.

Verify voltage to cooling fan terminals 120 VAC, see Wiring Diagram/Schematic for terminal identification.

Control surface Measure voltage at the following terminals L1 Com Inner Outer L1 to L2 …………………………………… L1 to Com………………………………… 240 VAC L2 L2 to Com………………………………… 120 VAC Com to Inner…………………………….. 120 VAC ON Com to Outer……………………………. 240 VAC LIGHTS 240 VAC

HOT

Sensor Connections

Thermostat See wiring diagram.

Closed ………………………………………. 165°F Open ………………………………………… 215°F

June 2003 3 16022397 Rev. 0

Wiring Diagram and Schematic

! WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

16022397 Rev. 0 JEC9530AD* June 2003

4

Wiring Diagram and Schematic

! WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

June 2003 JEC9536AD* 16022397 Rev. 0

5