[pdf-embedder url=’http://appliancetechmanuals.com/wp-content/uploads/whirlpool/tech-sheet-12728240.pdf’ title=’tech-sheet-12728240′]Wiring Diagram Technical Information Bottom Mount Refrigerator

! WARNING 596.72282202 596.72283202 596.72284202 596.72289202

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires service or repair of this refrigerator. removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. ! CAUTION

All safety information must be followed as provided in Service Manual

! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

No-Load Performance, Controls in Normal Position

Kw/24 hr ±0.4 Percent Run Time Cycles/24 hr Refrigerator Center Freezer Compartment 65° 90° 110° ±10% ±25% .9 1.5 2.1 Compartment Average Food Temperature ±3°F Average Food Temperature ±3°F

Ambient °F 65° 90° 110° 65° 90° 110° 65° 90° 110° 65° 90° 110° 22 cu ft 25 40 60 30 27 22 38 40 42 0 0 0

Temperature Relationship Test Chart

Evaporator Evaporator Suction Line Average Total Suction Head Pressure ±7°F Wattage ±10% ± 5 PSIG Outlet Inlet Pressure ±3°F ±3°F ±2 PSIG

Ambient °F 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 22 cu ft -15 -14 -15 -14 65 95 135 140 0 1 83 135

Schematic

April 2003 4 12728240 April 2003 1 12728240

Component Specifications 12566102 Adaptive Defrost Control (ADC)

! WARNING ! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

Part Number Component Specifications all parts 210/220 VAC The ADC adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the cold control and length the C8931612 Compressor run capacitor 115VAC/60HZ unless noted defrost heater is on. R0131673 Compressor 15 µfd ± 10% After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. Volt …………………………………………….. Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from the previous defrost interval. 67001041 Damper control Capacitance ……………………………….. 865 BTUH Each minute the thermostat opens prior to optimum defrost, it extends the next defrost interval 1 hr. When in defrost if defrost terminator opens 67001046 Freezer temperature control there is a 6 minute drip time before compressor restarts or ADC will terminate defrost at 30 minutes even if defrost thermostat has not opened and BTUH …………………………………………. 60 Hz / 168 watts will reset the defrost interval to the 8 hr. minimum setting. 10884507 Condenser motor Watt …………………………………………… 19.5 amps± 15% 4 hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours of compressor run time has 67002056 Evaporator fan motor Current Lock rotor ………………………… 1.35 amps± 15% also occurred. 67002527 Overload/Relay Current Full load ………………………….. 2.79 ohms± 15% Power up Refrigeration mode will occur unless both the cold control and defrost terminator are open, in that case the defrost mode will occur for 2 Resistance Run windings………………. 4.49 ohms± 15% minutes. 12001937 Thermostat (Defrost) Resistance Start windings……………… To Force Defrost: Turn cold control on and off 3 times within 6 seconds. Closing temperatures A forced defrost is immediate without any delay regardless of the cold control state or the defrost terminator state. (When the ADC cycles the unit 67001794 Evaporator heater Settings 34.0°F into defrost on it’s own defrost it is delayed until 4 minutes after the compressor has been cycled off by the cold control.) 12544002 Water Valve (primary) #1 ………………………………………………. 27.0°F Note: Cold control contacts must make and break for defrost to occur. In some cases freezer door must be left open to warm the cold control #4 ………………………………………………. 20.0°F sensing capillary up to get the cold control contact to make and break. If cold control contacts do not make and break unit will not force a defrost. #7 ………………………………………………. To Terminate Defrost: The only way to manually terminate defrost is to disconnect power to the unit. Unit will automatically come out of defrost at Temperatures the end of the normal defrost cycle. Settings -0.6°F ±3° #1 – out ………………………………………. 10.0°F ±1.5° Input Voltage Readings and Checks #4 – Differential……………………………. -8.0°F ±1.5° L1 to L2…………………………………………Line voltage should be present when the unit is powered #4 – out ………………………………………. -17.9°F ±3° CC to L2…………………………………………Line voltage should be present when the cold control contacts are closed and ADC is not in defrost. #7 – out ………………………………………. STAT to L2 ………………………………………..Line voltage should be present when the ADC is in defrost mode and the defrost terminator contacts are Clockwise Rotation (facing end opposite shaft) closed RPM 1100 RPM 8.6 watts±15%@115VAC Output Voltage Readings and Checks Watt……………………………………………. 0.11 amps± 15%@115VAC Current ……………………………………….. HTR to L2………………………………………Line voltage should be present when the ADC is in defrost mode

COMP to L2 Line voltage should be present when the ADC is not in the defrost mode.

Rotation (facing end opposite shaft) Clockwise Water Dispenser Seconds to dispense 10 oz. water RPM…………………………………… 2800 RPM Watt……………………………………. 5.9 ±15% watts@115VAC 5/16″ 5/16″x5/16″O.D. Supply pressure 20 psig 35 psig 45 psig 55 psig 75 psig Plastic Tubing Compression Union Filter model 10.4 8.0 7.0 6.0 5.0 Ult. trip amps @ 158°F (70°C) ……….. 3.51 amps± 15% Routed Thru a Close temperature ……………………… 142°F ±6° Conduit Foamed in Filter Bypass installed 17.2 11.5 10.0 8.5 7.0 Open temperature………………………. 257°F ±3° Place Filter model 10 seconds ±5 Water Short time trip (seconds)……………….. 14 amps ±2amps Water Reservoir New filter installed Short time trip (amps @77°F (25°C).. Dispenser 120/240 VAC Plastic Tubing A minimum supply pressure of 35 psig for water filter units. Volt ……………………………………………. 1000 watts Remove Water 5/16″ O.D. Minimum pressure requirement ensures that water valves close and Watt …………………………………………… 10/5 amps Tubing From sufficient water volume is available to fill icemaker. Proper fill is 140 cc. Current ……………………………………….. Conduit From of water in 7.5 seconds. Failure of water valves to close because of low Resistance across terminals: Open Dispenser End pressure will result in fill-tube freeze-up or dripping at cavity. Above 42°F ±5°……………………………. Closed Below 12°F ±7° ……………………………. Ice 115 VAC Maker Volt …………………………………………….. 450 ±5% watts @ 115VAC Wattage………………………………………. Resistance ………………………………….. 29 ±5% ohms

Watts …………………………………………. Brown side 35w, Purple side 20w

67003311 Water Valve (secondary) Watts …………………………………………. Brown side 35w, Purple side 20w

C3680310 Light switch Type…………………………………….. SPST NC Dispenser Water Temperature Volt……………………………………… 125/250 VAC Current………………………………….. 8 / 6 amps Water Usage 65°F Room 90°F Room

Type…………………………………….. SPDT NO/NC ounces Ambient Ambient Volt……………………………………… 125/250 VAC 12466101 Light switch / Interlock Current………………………………….. 8 / 6 amps 8 40.2°F 42.1°F

16 39.8°F 41.4°F

24 42.5°F 45.0°F

32 45.9°F 51.1°F

40 50.6°F 57.2°F

1/4″ OD 38°- 40°F fresh food temperature after 12 hours stabilized in Plastic Tubing water reservoir. Water capacity of tank is 36.5 ounces.

WATER DISPENSING FLOW

April 2003 2 12728240 April 2003 3 12728240