tech-sheet-12728220
Wiring Diagram Technical Information Bottom Mount Refrigerator

! WARNING Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires ! CAUTION removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. All safety information must be followed as provided in Service Manual 16021484.

! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

No-Load Performance, Controls in Normal Position

Kw/24 hr ±0.4 Percent Run Time Cycles/24 hr Refrigerator Center Freezer Compartment ±10% ±25% 65° 90° 110° Compartment Average Food .9 1.5 2.1 65° 90° 110° 65° 90° 110° Temperature ±3°F .9 1.4 2.0 Average Food Temperature ±3°F

Ambient °F 65° 90° 110° 65° 90° 110° 22 cu ft 19 cu ft 25 40 60 30 27 22 38 40 42 0 0 0

25 40 60 33 30 24 38 40 42 0 0 0

Temperature Relationship Test Chart

Evaporator Evaporator Suction Line Average Total Suction Head Pressure ±7°F Wattage ±10% ± 5 PSIG Outlet Inlet Pressure ±3°F ±3°F ±2 PSIG

Ambient °F 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 22 cu ft 19 cu ft -15 -14 -15 -14 65 95 135 140 0 1 83 135

-15 -14 -15 -14 65 95 135 140 0 1 83 135

Schematic

May 2002 4 12728220 May 2002 1 12728220

Component Specifications Damper Replacement

! WARNING ! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

Part Number Component Specifications all parts 210/220 VAC Replacing Damper Control C8931612 Compressor run capacitor 115VAC/60HZ unless noted R0131673 Compressor 15 µfd ± 10% 1. Remove lens cover by removing hex head screw in lens cover. Slide cover rearward and drop down to remove. Volt …………………………………………….. 67001041 Damper control Capacitance ……………………………….. 865 BTUH 2. Remove damper control cover and foam insert by pulling straight down on sides of rear cover and tilt forward 67001087 Freezer temperature control approximately ½” to 1″. This will release the cover from the tabs holding it in place. BTUH …………………………………………. 60 Hz / 168 watts 10884507 Condenser motor Watt …………………………………………… 19.5 amps± 15% FOAM INSERT 10449510 Evaporator fan motor Current Lock rotor ………………………… 1.35 amps± 15% 12555902 Overload/Relay Current Full load ………………………….. 2.79 ohms± 15% DAMPER CONTROL COVER Resistance Run windings………………. 4.49 ohms± 15% 12001937 Thermostat (Defrost) Resistance Start windings……………… 3. Release tension on damper control belt by squeezing tabs on bottom of belt tensioner to release tensioner Closing temperatures from it’s holding tabs. 12049801 Evaporator heater Settings 34.0°F 67001036 Defrost timer #1 ………………………………………………. 27.0°F BELT TENSIONER 12638801 Water valve #4 ………………………………………………. 20.0°F C3680310 Light switch #7 ………………………………………………. 4. Damper can be removed by pushing in tabs on left and right side of damper control to release damper from 12466101 Light switch / Interlock Temperatures rear wall. Settings -0.6°F ±3° #1 – out ………………………………………. 10.0°F ±1.5° #4 – in ………………………………………… -8.0°F ±1.5° #4 – out ………………………………………. -17.9°F ±3° #7 – out ………………………………………. Clockwise Rotation (facing end opposite shaft) RPM 1100 RPM 8.6 watts±15%@115VAC Watt……………………………………………. 0.11 amps± 15%@115VAC Current ………………………………………..

Rotation (facing end opposite shaft) Clockwise

RPM…………………………………… 2800 RPM Watt……………………………………. 5.9 ±15% watts@115VAC

Ult. trip amps @ 158°F (70°C) ……….. 3.51 amps± 15% Close temperature ……………………… Open temperature………………………. 142°F ±6°

Short time trip (seconds)……………….. 257°F ±3° Short time trip (amps @77°F (25°C).. 10 seconds ±5 14 amps ±2amps

Volt ……………………………………………. 120/240 VAC Watt …………………………………………… 1000 watts Current ……………………………………….. 10/5 amps Resistance across terminals: Above 42°F ±5°……………………………. Open Below 12°F ±7° ……………………………. Closed

Volt …………………………………………….. 115 VAC Wattage………………………………………. Resistance ………………………………….. 450 ±5% watts @ 115VAC 29 ±5% ohms

Volt…………………………………………….. 120VAC, 60 HZ Defrost period (minutes)……………….. 33 ± 3.6 Defrost cycle (hours)…………………… 8

Volt…………………………………………….. 110-120VAC, 60 HZ Watt……………………………………. 35 watts

Type…………………………………….. SPST NC RELEASE TABS Volt……………………………………… 125/250 VAC Current………………………………….. 8 / 6 amps 5. Install new damper in reverse order. When installing belt align large slots on belt with large cogs on damper and control knob gear. This will synchronize control knob with damper control. Type…………………………………….. SPDT NO/NC Volt……………………………………… 125/250 VAC 6. Install belt tensioner on mounting tabs and turn counter clockwise to increase tension on belt. Current………………………………….. 8 / 6 amps 7. Reinstall damper control cover by hooking bottom on tabs and rotating up until it snaps into place. 8. Reinstall lens by sliding lens cover forward on tabs and installing hex head screw.

May 2002 2 12728220 May 2002 3 12728220