Wiring Diagram and Schematic Technical Information Side by Side Refrigerator

! WARNING 596.52672200 596.52673200 596.52674200 596.52679200

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

service or repair of this refrigerator.

! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure propergrounding and polarization.

No-Load Performance, Controls in Normal Position

Kw/24 hr ±0.4 Percent Run Time Cycles/24 hr Refrigerator Center Freezer Compartment ±10% ±25% Compartment Average Food Temperature ±3°F Average Food Temperature ±3°F

Ambient °F 65° 90° 110° 65° 90° 110° 65° 90° 110° 65° 90° 110° 65° 90° 110° 26 cu ft 1.3 2.06 2.9 1 37 57 75 34 35 19 33 37 39 -5 -3

Temperature Relationship Test Chart

Evaporator Evaporator Suction Line Average Total Suction Head Pressure ±7°F Wattage ±10% ± 5 PSIG Outlet Inlet Pressure ±3°F ±3°F ±2 PSIG

Ambient °F 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 26 cu ft -25 -19 -24 -19 72 98 132 146 6″(vac.) 0 87 137

Component Specifications

Part Number Component Test Procedures 210/220 VAC C8931612 Compressor run capacitor Volt 15 µfd +10% Capacitance -5% R0131672 Compressor Type Fan Cooled, R134a refrigerant BTUH 865 BTUH 67002789 Auger Motor Volt 115 VAC, 60 Hz Watt 152 watts 12466104 Light switch Current Lock rotor 19.5 amps 12466101 Light switch / Interlock Full load 1.35 amps Resistance 12575401 Solenoid (Ice Chute) Run windings 2.79 ohms 12544002 Water Valve (primary) Start windings 4.49 ohms 12544102 Water Valve (secondary) Rotation (facing end opposite Power to blue and white is clockwise. Power to shaft) orange and white is counterclockwise RPM 17± 3 RPM Type SPST NC Volt 125/250 VAC Current 5/2.5 amps

Type SPDT NO/NC Volt 125/250 VAC Current 5/2.5 amps Resistance across leads 101ohms ± 10%

Watts Brown side 35w, Purple side 20w Watts Brown side 35w, Purple side 20w

December 2002 4 12728119 December 2002 1 12728119

Component Specifications 12566102 Adaptive Defrost Control (ADC)

! WARNING ! WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Part Number Component Test Procedures 12571701 Damper control The ADC adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the cold control and length 12351006 Freezer temperature control Settings Closing temperatures the defrost heater is on. B2150504 Drier #1 50.6°F After initial power up, defrost intervals are 6 hr.(initial), 8 hr.(minimum), 96 hr. (maximum). Defrost is delayed for 4 min. after the control R0131583 Condenser motor (ECM) #4 42.3°F cycles compressor off. 67001509 Evaporator fan motor #7 34.1°F Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next defrost interval 1 hr. ADC will terminate defrost at 12555902 Overload/Relay Settings Temperatures 30 minutes even if defrost thermostat has not opened and will reset the defrost interval to the 8 hr. minimum setting,. #1 – in 16.4°F ±3° A 6 minute delay occurs after defrost thermostat opens before compressor is allowed to run. If defrost thermostat opens within 30 seconds R0131454 Thermostat (Defrost) #4 – in 19.2°F ±1.5° of beginning of defrost, delay is by passed. #4 – out -4.9°F ±1.5° #7 – out -9.6°F ±3° Four hours of continuous compressor run will initiate a defrost, and defrost interval re-sets to 8 hours.

Drier must be changed every time the system is opened for testing or compressor Power up:If defrost thermostat is open, compressor is powered. replacement. If defrost thermostat is closed, defrost is powered.

Desiccant (20) 8 x 12 4AXH – 7 M>S> -Grams To Force or Terminate defrost: Toggle freezer door light switch 5 times within 6 sec If cold control is open, a forced defrost will not occur until the cold control closes, then the ADC will immediately switch the function to Volt 115 VAC, 60 Hz defrost. If cold control is closed and defrost terminator or heater circuit is open when defrost is forced, ADC shuts unit down momentarily and Rotation (facing end opposite shaft) Clockwise immediately restores power to refrigeration circuit. RPM 1250 RPM If cold control is closed, a forced defrost is immediate without any delay (When the ADC cycles the unit into defrost on it’s own defrost it is Watt 3.72 watts ± 15% delayed until 4 minutes after the compressor has been cycled off by the cold control.) When ADC is in defrost, cold control is closed and refrigeration is forced, ADC bypasses 6 minute dwell time. Current 0.06 amps

Volt 115 VAC, 60 Hz Input Voltage Readings and Checks

Rotation (facing end opposite shaft) Clockwise E2 to E4 ………………………………… Line voltage should be present when the unit is powered

RPM 2800 RPM E6 to E4 ………………………………… Line voltage should be present when the cold control contacts are closed Watt 5.9 ±15% watts E5 to E4 Line voltage should be present when the ADC is in defrost mode and the defrost terminator contacts are

Note: Fan blade must be fully seated on closed shaft to achieve proper airflow. E7 to E4 ………………………………… Line voltage should be present when the freezer door is open (freezer light switch closed)

Volt 125 VAC Output Voltage Readings and Checks E1 to E4 ………………………………… Line voltage should be present when the ADC is in defrost mode Ult. trip amps @ 158°F (70°C) 3.51 amps E3 to E4 ………………………………… Line voltage should be present when the ADC is not in the defrost mode or compressor dwell mode

Close temperature 142°F ±6°

Open temperature 257°F ±3° Dispenser Operation Short time trip (seconds) 10 seconds ±5 Dispenser Operation Short time trip (amps @77°F (25°C) 14 amps Select WATER, CRUSHED or CUBED mode by pushing the button on the dispenser panel. A green indicator light above the button indicates the Volt 120/240 VAC current selection. Selection mode cannot be changed from CRUSHED to CUBED or from CUBED to CRUSHED while ice dispenser is in operation.

Watt 1000 watts Dispenser Light

Current 10/5 amps Light activates at full power when dispensing ice or water. A sensor activates light at half-power when light level around refrigerator is low. Activate or deactivate sensor by pushing AUTO LIGHT button located on control façade. Green light above AUTO LIGHT button indicates sensor Resistance across terminals: is active. Dispenser Lock Above 45°F ±5° Open Prevents operation of water and ice dispensers. To activate or deactivate lock, press and hold DISPENSER LOCK button for 3 seconds. Green light above button indicates dispenser lock. Below 15°F ±7° Closed Automatic Lock Out Shuts down both ice and water mechanisms of dispenser when either mechanism has run continuously for 3 minutes. To return power to Between 45°F ±5° and Will stay in current state (open or dispenser, press and hold DISPENSER LOCK for 3 seconds. Auger motor shuts off automatically after 3 minutes of continuous operation. After 15°F ±7° closed) until either 45°F ±5° or 15°F about 3 minutes in shut-off state, auger motor resets automatically. ±7° is reached. Filter Status Light This feature reminds users to replace water filter after 6 months have passed or after 500 gallons of water are filtered, whichever happens Seconds to dispense 10 oz. water first.

Supply pressure 35 psig 45 psig 55 psig 75 psig NOTE: Filter status light turns red after 6 months have passed or after 500 gallons of water are dispensed, even if bypass is installed and unit is used without filter cartridge. Filter model 9.0 8.0 7.0 6.0 Green light indicates filter in good condition. Red light indicates filter replacement needed. Bypass installed The filter monitor works by keeping track of time: Six months is approximately 16 million seconds. Filter model 11.0 10.0 8.0 7.0 The refrigerator’s water system requires about 53,000 seconds to pass 500 gallons of water. New filter installed Each second that water is dispensed counts as 1.20 ounces of water. A minimum supply pressure of 35 psig for water filter units. Minimum pressure requirement ensures that water valves close and sufficient water volume is available to fill icemaker. An additional 3.20 ounces of water is counted every 30 minutes. This attempts to account for ice usage. Proper fill is 140 cc. of water in 7.5 seconds. Failure of water valves to close because of low pressure Filter Status Light Reset will result in fill-tube freeze-up or dripping at cavity. Once filter light turns red, it remains red until reset. To reset filter indicator, press both DISPENSER LOCK and WATER pushbuttons simultaneously and hold for 4 seconds. Make sure green light flashes 3 times when indicator resets.

December 2002 2 12728119 December 2002 3 12728119