MODELS 596.71812100, 596.71814100, 596.71813100, 596.71819100, 596.71812101, 596.71814101, 596.71813101,596.71819101, 596.61802100, 596.61804100, 596.61803100, 596.61809100, 596.61802101,
596.61804101, 596.61803101, 596.61809101
DISCONNECT POWER CORD BEFORE SERVICING. IMPORTANT: RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be returned to original position and properly fastened.
ELECTRICAL SPECIFICATIONS
Freezer Control (Mid-Position) ………………………. +5° -7°F Defrost Control …………………………………………. 8 hr Timer
Defrost time 33 ±4 min. Defrost Thermostat …………………… Open 55°, Close 20°F Electrical Rating: ……………. 115 VAC, 60 HZ, 5.43 Amps Maximum Current Leakage …………………………….0.75 ma Maximum Grounding Resistance …………………. 0.1 Ohms *Running Watts ………………. 65° …………….. 150 W ±10% …………………………………….. 90° …………….. 160 W ±10% Compressor Locked Rotor Amps(12555802) ……………….. …………………………………………………………….. 19.2 Amps *Avg total watts over entire run cycle
NO LOAD PERFORMANCE
Control Position Mid/Mid and Ambient of:
65°F 90°F
Fresh Food °F 37° ±3°F 40° ±3°F Frozen Food °F 1° ±3°F 1° ±3°F Percent Run Time 22 ±10% 39 ±10%
REFRIGERATION SYSTEM
Refrigerant Charge (R134a) ……………………………….4.5 oz Compressor (Tec)12409717 ……………………… 865 BTU/Hr Compressor(Pan) 12555802……………………….901BTU/Hr
KEY FUNCTIONAL PARTS w/Ohm Reading (where applicable)
Evaporator Fan Motor 12442205 2040 Condenser Fan Motor 10884507 250 ±10% Compressor/Tec 12049717 Start 4.35 ±10% Run 2.6 ±10% Compressor/Pan 12555802 Start 4.64±7% Run 3.37±7%
Evaporator Heater 12219401 29 ±10% Damper Control R0161050 Freezer Control C8946703 13100 ±10% Defrost Timer 10530703 340 ±10% Service Drier B2150504 Water Valve 12490801
TECH SHEET 10096872
MODELS 596.71812100, 596.71814100, 596.71813100, 596.71819100, 596.71812101, 596.71814101, 596.71813101,596.71819101, 596.61802100, 596.61804100, 596.61803100, 596.61809100, 596.61802101,
596.61804101, 596.61803101, 596.61809101