SPECIFICATIONS: STAMP

THERMISTOR INPUT TO CONTROL: – HARVEST ICE ONCE THERMISTOR INPUT REACHES -13°C/8.6°F OR AFTER 100 MIN WATER FILL – 117 CC (mL), 13.5 SEC. CYCLE – ONE TWIST PROCESS INPUT VOLTAGE: 120 V & 240 V MODELS

NOTE: 24 HRS ICE MAKER MAKE 56 TO 72 ICE CUBES. THIS FLOW DIAGRAM IS ONLY FOR TEST SWITCH MODE THE ICE MAKER REQUIRED 2 – 3 DAYS TO FILL THE ICE BIN CONTAINER. (THE REFRIGERATOR REQUIRED 3 HOURS TO ESTABILIZATION)

SERVICE PROCEDURES PRESS AND HOLD FOR *MAKE SURE THE ICE MAKER IS ON 3 SEC (TEST SWITCH) BEFORE PRESSING THE TEST SWITCH. MODULE MOTOR – THE ON/OFF SWITCH (MAIN SWITCH) AND THE TEST SWITCH ARE LOCATED THERMISTOR CHECK FAILS AT THE BOTTOM OF THE ICE MAKER. (OPEN OR CLOSE) ICE MAKER STOP MAIN SWITCH – PASS REPLACE THE ICE MAKER TURN THE MAIN SWITCH TO ON POSITION (AS SHOWN IN THE PICTURE BELOW), TO ENSURE ICE MAKER WILL WORK. ICE MAKER START TO TWIST TRAY TEST SWITCH – PRESS AND HOLD FOR 3 SECONDS; THE TEST SWITCH WILL BYPASS THE DETECTION OF THE ICE FULL TIMER AND TEMPERATURE (THERMISTOR TEMPERATURE -13°C/8.6°F) AND QUANTITY (BAIL ARM WILL START TEST SEQUENCE. MOVEMENT)

TEST SEQUENCE BELOW. MONITOR TEST FOR NORMAL CONDITIONS. IF NO FULL TEST COMPLETES FULL CYCLE WITHOUT ABNORMAL CONDITION, ICE MAKER IS WORKING AND OPERATIONAL. ICE EJECTION

HOME POSITION – RETURN HOME POSITION RETURN HOME POSITION THE ICE TRAY WILL MOVE TO HOME POSITION ONCE TURNED ON THE ICE MAKER OR AFTER A POWER RESET THEN STARTS THE TWIST PROCESS. WATER FILL 6.8 SEC IF THE CONTAINER (~60 ml / ~2 OZ) IS NOT FULL, BAIL ARM – CHECK BAIL ARM AT THE SAME TIME AS THE TWIST PROCESS, THE BAIL ARM WILL GO DOWN WATER FLOW STOP FOR INTERFERENCE TO DETECT THE ICE LEVEL. 3 SEC

WATER VALVE – WATER FILL 6.8 SEC IF YOU DO NOT WANT TO PUT WATER DIRECTLY INTO THE TRAY, REMOVE (~60 ml / ~2 OZ) FILL CHUTE AND CATCH WATER WITH A DISPOSABLE CUP.

THE VALVE WILL OPEN FOR 6.8 SECONDS TO DELIVER A HALF AMOUNT OF WATER INTO THE TRAY. THE WATER FLOW WILL STOP FOR THREE SECONDS THEN THE VALVE WILL RE-OPEN FOR 6.8 SECONDS TO COMPLETE THE FILL (117 mL). IF THE VALVE COMPLETES THE WATER FILL IN THE SPECIFIED VOLUME AND TIME, THE ICE MAKER IS WORKING AND IS FULLY OPERATIONAL.

NOTE: IF THE WATER VALVE OPERATES ONLY ONCE, IT MEANS SOMETHING IN THE ICE MAKER IS WRONG (COULD BE BAIL ARM OR ICE MAKER MOTOR).

END BOTTOM VIEW TEST SWITCH

MAIN SWITCH MAIN SWITCH – ON MAIN SWITCH – OFF

W11218398B In some European factories the letter “W” of the part code mentioned herein will be au1tomatically 22-Oct-2019 18:34:38 EDT ” RELEASED replaced by the number “4000” (e.g. “W12345678” becomes “400012345678”)

FEUILLE DE SERVICE DE LA MACHINE A GLAÇONS SPECIFICATIONS:

ENTRÉE DE THERMISTOR POUR CONTRÔLER: – LA RÉCOLTE GLACE UNE LABEL FOIS L’ENTRÉE DE THERMISTOR ATTEINT -13°C/8.6°F OU APRÈS 100 MIN REMPLISSAGE D’EAU -117 CC (mL), 13.55 SEG. CYCLE – PROCEDURE D’UNE TORSION TENSION D’ENTREE : MODELES DE 120 V & 240 V

NOTE: UNE MACHINE A GLAÇONS DE 24 HRS FAIT ENTRE 56 ET 72 CUBES L’ORGANIGRAMME EST SEULEMENT POUR LE MODE DE GLACE. D’ESSAI D’INTERRUPTEUR LA MACHINE A GLAÇONS A BESOIN DE 2-3 JOURS POUR REMPLIR LE BAC A GLACE. (LE REFRIGERATEUR A BESOIN DE 3 HEURES POUR APPUYEZ ET *ASSUREZ-VOUS QUE STABILISATION) MAINTENEZ POUR 3 SEC L’INTERRUPTEUR SOIT ALLUME (INTERRUPTEUR D’ESSAI) PROCEDURES DE SERVICE AVANT D’APPUYER

MODULE MOTEUR – CONTROLE DE ÉCHOUE LA MACHINE A GLAÇONS L’INTERRUPTEUR ON/OFF (INTERRUPTEUR PRINCIPALE) ET THERMISTEUR (OUVERT OU S’ARRETE L’INTERRUPTEUR D’ESSAI SONT LOCALISES EN BAS DE LA MACHINE A GLAÇONS. FERME) REMPLACEZ LA MACHINE A GLAÇONS INTERRUPTEUR PRINCIPAL – REUSSI TOURNEZ L’INTERRUPTEUR PRINCIPAL A LA POSITION ON (COMME LE MONTRE L’ILLUSTRATION CI-DESSOUS), POUR ASSURER QUE LA LA MACHINE A GLAÇONS MACHINE A GLAÇONS VA MARCHER. COMMENCE LA TORSION

DU BAC

INTERRUPTEUR D’ESSAI – DETECTION DE LA QUANTITE PLEIN APPUYEZ ET MAINTENEZ POUR 3 SECONDES ; L’INTERRUPTEUR DE GLAÇON (MOUVEMENT D’ESSAI VA CONTOURNER LE CHRONOMETREUR ET LA TEMPERATURE DU BRAS D’ETIER) (TEMPERATURE DE THERMISTANCE -13ºC/8.6ºF). SEQUENCE D’ESSAI AUCUN PLEIN CI-DESSOUS. TEST DU MONITEUR POUR CONDITIONS NORMAUX. SI L’ESSAI TERMINE UN CYCLE COMPLET SANS SITUATION ANORMALE, LA EXPULSION DE GLAÇON MACHINE A GLAÇON TRAVAILLE ET EST OPERATIONNEL.

POSITION DE DEPART – RETOUR A LA POSITION LE BAC A GLAÇON VA SE DEPLACER A LA POSITION DE DEPART UNE DE DEPART FOIS QUE LA MACHINE A GLAÇONS SOIT ALLUME OU APRES UNE REINITIALISATION, ENSUITE LE PROCESSUS DE TORSION COMMENCE.

BRAS D’ETRIER – REMPLISSAGE D’EAU 6.8 SEC RETOUR A LA POSITION DE AU MEME TEMPS QUE LE PROCESSUS DE TORSION, LE BRAS D’ETRIER (~60 ml / ~2 OZ) DEPART VA DESCENDRE POUR DETECTER LE NIVEAU D’EAU. (SI LE CONTENEUR N’EST ARRET D’ECOULEMENT PAS PLEIN VERIFIEZ S’IL VANNE D’EAU – D’EAU PENDANT 3 SEC Y A D’INTERFERENCE SI VOUS NE VOULEZ PAS AJOUTER DE L’EAU DIRECTEMENT DANS LE DANS LE BRAS D’ETRIER) PLATEAU, ENLEVEZ LA GLISSIERE DE REMPLISSAGE ET ATTRAPEUR REMPLISSAGE D’EAU 6.8 SEC L’EAU AVEC UN GOBELET JETABLE. (~~60 ml / ~~2 OZ) VUE DE DESSOUS

LA VANNE VA S’OUVRIR PENDANT 6.8 SECONDES POUR LIVRER LA FIN MOITIE D’EAU DANS LE BAC. LA CHUTE D’EAU S’ARRETERA POUR TROIS SECONDES, APRES LE VANNE VA SE REOUVRIR PENDANT 6.8 SECONDES INTERRUPTEUR D’ESSAI POUR COMPLETER LE REMPLISSAGE (117 mL). SI LA VANNE TERMINE LE REMPLISSAGE D’EAU DANS LE VOLUME ET TEMPS SPECIFIE, LA MACHINE A GLAÇONS TRAVAILLE ET EST COMPLETEMENT OPERATIONNEL.

NOTE: SI LA VANNE D’EAU FONCTIONNE SEULEMENT UNE FOIS, CELA VEUT DIRE QUE QUELQUE CHOSE NE VA PAS (CELA PEUT ETRE LE BRAS D’ETRIER OU LE MOTEUR DE LA MACHINE A GLAÇONS).

INTERRUPTEUR PRINCIPAL ON

INTERRUPTEUR PRINCIPAL – OFF

INTERRUPTEUR In ©2019 All rights reserved. “W” of the part code mentioned herein will be1a0u/t1o9matically PRINCIPALE` some TEouurospderaonitfsarcétosreirevsétsh.e letter replaced by the number “4000” (e.g. “W12345678” becomes “400012345678”) W11218398B 22-Oct-2019 18:34:38 EDT ” RELEASED